F3SJA0815P20 Omron, F3SJA0815P20 Datasheet - Page 66

no-image

F3SJA0815P20

Manufacturer Part Number
F3SJA0815P20
Description
Manufacturer
Omron
Datasheet

Specifications of F3SJA0815P20

Lead Free Status / Rohs Status
Compliant
Setting Bi-directional Muting
Note: 1. This example arrangement uses E3Z-R@@ Retro-reflective Photoelectric Sensors as the muting sensors. Mutual interference must be
A1, A2, B1, B2: Retro-reflective
Photoelectric Sensors
Connect the outer muting sensors A1 and A2 to muting input 1 and the inner muting sensors B1 and B2 to muting input 2.
When muting sensors A1 and then B1 (or A2 and then B2) turn ON in that order, the F3SJ will enter the muting state.
Muting from the opposite direction is also possible.
2. The muting sensors must be installed so that distance D between muting sensors A1 and A2 is smaller than workpiece length L.
3. Through-beam or Retro-reflective Photoelectric Sensors, Proximity Sensors, or Limit Switches can be used as the muting sensors.
taken into account when installing these Sensors.
Two-wire sensors cannot be used.
Workpiece
L
A1
B1
F3SJ
A1
B2 A2
B1
F3SJ
D
B2 A2
V
Connected to muting input 1
Connected to muting input 2
Workpiece
Reflector
F3SJ Ver.2
66