DS18S20 Maxim Integrated Products, DS18S20 Datasheet - Page 16

no-image

DS18S20

Manufacturer Part Number
DS18S20
Description
Board Mount Temperature Sensors
Manufacturer
Maxim Integrated Products
Datasheet

Specifications of DS18S20

Full Temp Accuracy
+/- 2 C
Package / Case
TO-92
Digital Output - Bus Interface
Serial (1-Wire)
Digital Output - Number Of Bits
9 bit
Maximum Operating Temperature
+ 125 C
Minimum Operating Temperature
- 55 C
Output Type
Digital
Lead Free Status / Rohs Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
DS18S20
Manufacturer:
SHARP
Quantity:
17 690
Part Number:
DS18S20
Manufacturer:
DALLAS
Quantity:
20 000
Part Number:
DS18S20+
Manufacturer:
Maxim
Quantity:
12 047
Part Number:
DS18S20+
Manufacturer:
DIODES
Quantity:
6 000
Part Number:
DS18S20+
Manufacturer:
MAXIM
Quantity:
8 000
Part Number:
DS18S20+
Manufacturer:
MAXIM/美信
Quantity:
20 000
Part Number:
DS18S20+PAR
Manufacturer:
MAXIM/美信
Quantity:
20 000
Part Number:
DS18S20+T&R
Manufacturer:
MAXIM
Quantity:
4 000
Part Number:
DS18S20+T&R
0
Part Number:
DS18S20+TR
Manufacturer:
ST
Quantity:
2 191
Part Number:
DS18S20Z
Manufacturer:
MAXIM/美信
Quantity:
20 000
Part Number:
DS18S20Z+
Manufacturer:
Maxim
Quantity:
2 943
Part Number:
DS18S20Z+T&R
Manufacturer:
MAXIM
Quantity:
500
Part Number:
DS18S20Z+T&R
0
The DS18B20 samples the 1-Wire bus during a window that lasts from 15µs to 60µs after the master
initiates the write time slot. If the bus is high during the sampling window, a 1 is written to the DS18B20.
If the line is low, a 0 is written to the DS18B20.
Figure 14. Read/Write Time Slot Timing Diagram
READ TIME SLOTS
The DS18B20 can only transmit data to the master when the master issues read time slots. Therefore, the
master must generate read time slots immediately after issuing a Read Scratchpad [BEh] or Read Power
Supply [B4h] command, so that the DS18B20 can provide the requested data. In addition, the master can
generate read time slots after issuing Convert T [44h] or Recall E
of the operation as explained in the DS18B20 Function Commands section.
All read time slots must be a minimum of 60µs in duration with a minimum of a 1µs recovery time
between slots. A read time slot is initiated by the master device pulling the 1-Wire bus low for a
minimum of 1µs and then releasing the bus (see Figure 14). After the master initiates the read time slot,
the DS18B20 will begin transmitting a 1 or 0 on bus. The DS18B20 transmits a 1 by leaving the bus high
and transmits a 0 by pulling the bus low. When transmitting a 0, the DS18B20 will release the bus by the
end of the time slot, and the bus will be pulled back to its high idle state by the pullup resister. Output
1-WIRE BUS
1-WIRE BUS
V
GND
V
GND
PU
PU
> 1µs
OF SLOT
START
15µs
15µs
LINE TYPE LEGEND
MASTER WRITE “0” SLOT
MASTER READ “0” SLOT
60µs < T
MIN
Master samples
15µs
Bus master pulling low
Resistor pullup
DS18B20 Samples
X
“0” < 120µs
TYP
45µs
30µs
16 of 22
MAX
> 1 µs
OF SLOT
START
DS18B20 pulling low
15µs
15µs
1µs < T
1µs < T
2
[B8h] commands to find out the status
MASTER WRITE “1” SLOT
> 1µs
MASTER READ “1” SLOT
REC
REC
MIN
<
<
Master samples
15µs
DS18B20 Samples
TYP
30µs
MAX
DS18B20

Related parts for DS18S20