VX2110-01T-3CR1 SMC Corporation, VX2110-01T-3CR1 Datasheet - Page 42

no-image

VX2110-01T-3CR1

Manufacturer Part Number
VX2110-01T-3CR1
Description
Process Solenoid Valve, 2 port, direct operated, 1/8 port, NC, 110VAC, conduit
Manufacturer
SMC Corporation
Type
Direct Operatedr
Datasheet

Specifications of VX2110-01T-3CR1

Brand/series
VX Series
Number Of Ports
2
Primary Type
Solenoid Valve
Size, Port
1⁄8" NPTF
Voltage, Coil
110 VAC
Enclosure
Equivalent to IP65
1. Cannot be used as an emergency shutoff
2. Extended periods of continuous energization
3. This solenoid valve cannot be used for explo-
4. Maintenance space
5. Liquid rings
6. Actuator drive
7. Pressure (including vacuum) holding
8. When the conduit type is used as equivalent
9. When an impact, such as water hammer, etc.,
1. Confirm the specifications.
2. Fluid
valve, etc.
The valves presented in this catalog are not designed for safety
applications such as an emergency shutoff valve. If the valves
are used in this type of system, other reliable safety assurance
measures should also be adopted.
The solenoid coil will generate heat when continuously
energized. Avoid using in a tightly shut container. Install it in a
well-ventilated area. Furthermore, do not touch it while it is
being energized or right after it is energized.
sion proof applications.
The installation should allow sufficient space for maintenance
activities.
In cases with a flowing liquid, provide a by-pass valve in the
system to prevent the liquid from entering the liquid seal circuit.
When an actuator, such as a cylinder, is to be driven using a
valve, take appropriate measures to prevent potential danger
caused by actuator operation.
It is not usable for an application such as holding the pressure
(including vacuum) inside of a pressure vessel because air
leakage is entailed in a valve.
to an IP65 enclosure, install a wiring conduit,
etc.
caused by the rapid pressure fluctuation is
applied, the solenoid valve may be damaged.
Give an attention to it.
Give careful consideration to the operating conditions such as
the application, fluid and environment, and use within the
operating ranges specified in this catalog.
1) Type of fluid
2) Flammable oil, Gas,
Before using a fluid, confirm whether it is compatible with the
materials from each model by referring to the fluids listed in
this catalog. Use a fluid with a dynamic viscosity of 50 mm
or less. If there is something you do not know, please contact
us.
Confirm the specification for leakage in the interior and/or
exterior area.
Warning
Warning
2 Port Solenoid Valve for Fluid Control
Precautions 1
Be sure to read this before handling.
For detailed precautions on each series, refer to the main text.
Selection
Design
2
/s
3. Fluid quality
5. Ambient environment
6. Countermeasures against static electricity
7. For the low particle generation specification,
4. Air quality
3) Corrosive gas
4) Use an oil-free specification when any oily particle must not
5) Applicable fluid on the list may not be used depending on the
The use of a fluid which contains foreign matter can cause
problems such as malfunction and seal failure by promoting
wear of the valve seat and armature, and by sticking to the
sliding parts of the armature, etc. Install a suitable filter (strainer)
immediately upstream from the valve. As a general rule, use 80
to 100 mesh.
When used to supply water to boilers, substances such as
calcium and magnesium which generate hard scale and sludge
are included. Since this scale and sludge can cause the valve to
malfunction, install water softening equipment, and a filter
(strainer) directly upstream from the valve to remove these
substances.
1) Use clean air.
2) Install air filters.
3) Install an air dryer or after cooler, etc.
4) If excessive carbon powder is generated, eliminate it by
Refer to SMC’s Best Pneumatics 2004 Vol. 14 catalog for
further details on compressed air quality.
Use within the operable ambient temperature range. Confirm
the compatibility between the product’s composition materials
and the ambient atmosphere. Be sure that the fluid used does
not touch the external surface of the product.
Take measures to prevent static electricity since some fluids can
cause static electricity.
confirm us separately.
Cannot be used since it will lead to cracks by stress corrosion
or result in other incidents.
enter the passage.
operating condition. Give adequate confirmation, and then
determine a model, just because the compatibility list shows
the general case.
Do not use compressed air which includes chemicals,
synthetic oils containing organic solvents, salt or corrosive
gases, etc., as it can cause damage or malfunction.
Install air filters close to valves at their upstream side. A
filtration degree of 5 m or less should be selected.
Compressed air that includes excessive drainage may cause
malfunction of valves and other pneumatic equipment. To
prevent this, install an air dryer or after cooler, etc.
installing mist separators at the upstream side of valves.
If excessive carbon powder is generated by the compressor,
it may adhere to the inside of the valves and cause a
malfunction.
Warning
Selection
Back page 2