ESX10-124-DC24V-10A E-T-A Circuit Protection and Control, ESX10-124-DC24V-10A Datasheet - Page 2

no-image

ESX10-124-DC24V-10A

Manufacturer Part Number
ESX10-124-DC24V-10A
Description
CIRCUIT PROTECTOR; 10 A CLASS I, DIVISION 2 ; RESET INPUT AND STATUS OUTPUT ; 24
Manufacturer
E-T-A Circuit Protection and Control
Type
Electronicr
Datasheet

Specifications of ESX10-124-DC24V-10A

Actuator Type
Toggle
Brand/series
ESX10
Current, Rating
10 A
Mounting Type
Plug-In
Number Of Poles
1
Termination
Blade
Voltage, Rating
24 VDC
Lead Free Status / Rohs Status
RoHS Exempt Product
5
Status output SF
Electrical data
Status OUT
Status OUT
OFF condition
Signal output F
Electrical data
ON condition LED green
OFF condition LED off
Fault condition LED orange overload condition > 1.1 x I
Fault condition LED red
ESX10-101
ESX10-102
ESX10-103
ESX10-105/-106/-115/-125 group signal, make contact
Fault
5 - 28
Attention: when mounted side-by-side without convection the ESX10-0.. should not
current rating
I
Technical data
Table 1: voltage drop, current limitation, max. load current
N
0.5 A
1 A
2 A
3 A
4 A
6 A
8 A
10 A
12 A
carry more than 80 % of its rated load with 100 % ON duty due to thermal effects.
typically voltage drop active current
U
70 mV
80 mV
130 mV
80 mV
100 mV
130 mV
120 mV
150 mV
180 mV
ON
at I
N
Electronic Circuit Protector ESX10
(T ambient = 25°C, operating voltage U S = DC 24 V)
ESX10-104/-106/-124/-127
plus-switching signal output,
connects U
nominal data: DC 24 V / max. 0.2 A (short
circuit proof)
status output is internally connected to
GND with a 10 kOhm resistor
ESX10-104/-106/ -124 (signal status OUT),
at U
+24 V = S1 is ON, load output connected
through 0V = S1 is ON, load output
blocked and/or switch S1 is OFF
ESX10-127 (signal status OUT inverted),
at U
+24 V = S1 is ON, load output blocked,
red LED lighted
0 V = S1 is ON, load output connected
through and/or switch S1 is in OFF position
0 V level at status output when:
ESX10-101/-102/-103/-105/-106/-115/-125
potential-free signal contact
max. DC 30 V/0.5 A, min. 10 V/10 mA
voltage U
position
no overload, no short circuit
electronic disconnection
electronic disconnection upon
overload or short circuit
device switched off with control signal
(switch S1 is in ON position)
single signal, make contact
contact SC/SO-SI open
single signal, break contact
contact SC/SO-SI closed
group signal change-over contact
contact SC-SO open, SC-SI closed
contact SC-SO open
signal output fault conditions:
red LED lighted (electronic disconnection)
switch S1 is in ON position, but device is
still in switch-on delay
switch S1 is OFF, or control signal OFF,
device is switched off
no operating voltage U
device switched off
(switch S1 is in OFF position)
no voltage U
no operating voltage U
ON/OFF switch S1 is in OFF position
S
S
limitation (typically) T
= +24 V
= +24 V
1.8 x I
1.8 x I
1.8 x I
1.8 x I
1.8 x I
1.8 x I
1.5 x I
1.5 x I
1.3 x I
S
S
N
N
N
N
N
N
N
N
N
applied, switch S1 is in ON
to terminal 12 of module 17plus
S
applied
max. load current at 100 % ON duty
U
= 40 °C
0.5 A
1 A
2 A
3 A
4 A
6 A
8 A
10 A
12 A
S
S
N
up to
T
U
= 50 °C
0.5 A
1 A
2 A
3 A
4 A
5 A
7 A
9 A
10.8 A
www.e-t-a.com
Reset input RE
Electrical data
Reset signal RE
(= terminal 13,14 or 12
of Module 17plus)
Caution: unused slots
have to be fitted with
jumpers
Control input IN+
Electrical data
Control signal IN+
Switch S1 ON/OFF
General data
Fail-safe element:
Blade terminals
Housing
Mounting
Ambient temperature
Storage temperature
Humidity
Vibration
Degree of protection
EMC
(EMC directive, CE logo)
Insulation co-ordination
(IEC 60934)
dielectric strength
Insulation resistance
(OFF condition)
Approvals
Dimensions (W x H x D)
Mass
Technical data
(T ambient = 25°C, operating voltage U S = DC 24 V)
ESX10-124/-125/-127
voltage: max. + DC 32 V
high > DC 8 V ≤ DC 32 V
low ≤ DC 3 V > 0 V
power consumption typically 2.6 mA
(+DC 24 V)
min. pulse duration typically 10 ms
The electronically blocked ESX10-124/-127
may remotely be reset via an external
momentary switch due to the falling edge of
a +24 V pulse.
The reset signal will be fed in terminal 13, 14
or 12 of Module 17plus and is internally
pre-wired.
The reset simultaneously affects all blocked
ESX10-124/-127 channels of the power
distribution system, all switched on
ESX10-124/-127 channels remain
unaffected. With type ESX10-125 the reset
only affects the device concerned. By
connecting the individual terminals 12 of
the Module 17plus a joint reset signal for
all ESX10-125 may be generated.
ESX10-115
see reset input RE
+24 V level (HIGH): device will be switched
on by a remote ON/OFF signal
0 V level (LOW): device will be switched
off by a remote ON/OFF signal
unit can only be switched on with S1 if a
HIGH level is applied to IN+
backup fuse for ESX10 not required
because of the integral
redundant fail-safe element
6.3 mm to DIN 46244-A6.3-0.8
moulded
plug-in mounting utilising power distribution
system Module 17plus or SVSxx
0...+50 °C
(without condensation, see EN 60204-1)
-20...+70 °C
96 hrs/95 % RH/40 °C to
IEC 60068-2-78, test Cab.
climate class 3K3 to EN 60721
3 g, test to IEC 60068-2-6 test Fc
housing: IP30 DIN 40050
terminals: IP00 DIN 40050
emission: EN 61000-6-3
susceptibility: EN 61000-6-2
0.5 kV/2 pollution degree 2
re-inforced insulation in operating area
max. DC 32 V (load circuit)
n/a, only electronic disconnection
UL 2367, File # E306740
Solid State Overcurrent Protectors
UL 508, File # E322549
CSA C22.2 No: 14, File 16186
CE logo
12.5 x 70 x 60 mm
approx. 40 g
Issue C