ICS1893YI-10LF IDT, Integrated Device Technology Inc, ICS1893YI-10LF Datasheet - Page 50

no-image

ICS1893YI-10LF

Manufacturer Part Number
ICS1893YI-10LF
Description
PHYCEIVER LOW PWR 3.3V 64-TQFP
Manufacturer
IDT, Integrated Device Technology Inc
Series
PHYceiver™r
Type
PHY Transceiverr
Datasheets

Specifications of ICS1893YI-10LF

Protocol
MII
Voltage - Supply
3.14 V ~ 3.47 V
Mounting Type
Surface Mount
Package / Case
64-TQFP, 64-VQFP
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Number Of Drivers/receivers
-
Lead Free Status / Rohs Status
Compliant
Other names
1893YI-10LF

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
ICS1893YI-10LF
Manufacturer:
IDT
Quantity:
390
Part Number:
ICS1893YI-10LF
Manufacturer:
IDT, Integrated Device Technology Inc
Quantity:
10 000
Part Number:
ICS1893YI-10LF
Manufacturer:
IDT
Quantity:
20 000
Part Number:
ICS1893YI-10LFT
Manufacturer:
IDT, Integrated Device Technology Inc
Quantity:
10 000
6.4 Functional Block: 100Base-TX TP-PMD Operations
6.4.1 100Base-TX Operation: Stream Cipher Scrambler/Descrambler
6.4.2 100Base-TX Operation: MLT-3 Encoder/Decoder
6.4.3 100Base-TX Operation: DC Restoration
ICS1893Y-10 Rev F 1/20/04
The ICS1893Y-10 supports both 10Base-T and 100Base-TX operations. For 100Base-TX operations, the
TP-PMD module performs stream-cipher scrambling/descrambling and MLT-3 encoding/decoding (3-level,
multi-level transition) in compliance with the ANSI Standard X3.263: 199X FDDI TP-PMD as defined in the
specification for 100Base-TX Twisted-Pair Physical Media Dependent (TP-PMD) Sublayer. The
ICS1893Y-10’s TP-PMD also performs DC restoration (that is, baseline wander correction) and adaptive
equalization on the received signals.
Note:
1. For an overview of 100Base-TX operations, see
2. For more information on the Twisted-Pair Interface, see
When the ICS1893Y-10 is operating in 100Base-TX mode, it employs a stream cipher
scrambler/descrambler that complies with the ANSI Standard X3.263: 199X FDDI TP-PMD. The purpose of
the stream cipher scrambler is to spread the transmission spectrum to minimize electromagnetic
compatibility problems. The stream cipher descrambler restores the received serial bit stream to its
unscrambled form.
The ICS1893Y-10 “seeds” (that is, initializes) the Transmit Stream Cipher Shift register by using the
ICS1893Y-10 PHY address from
The MAC/Repeater Interface bypasses the stream cipher scrambler/descrambler when in the 100M
Symbol Interface mode.
When operating in the 100Base-TX mode, the ICS1893Y-10 TP-PMD sublayer employs an MLT-3 encoder
and decoder. During data transmission, the TP-PMD encoder converts the NRZI bit stream received from
the PMA sublayer to a 3-level Multi-Level Transition code. The three levels are -1, 0, and +1. The results of
MLT-3 encoding provide a reduction in the transmitted energy over the critical frequency range from 20
MHz to 100 MHz. The TP-PMD MLT-3 decoder converts the received three-level signal back to an NRZI bit
stream.
The ICS1893Y-10’s 100Base-TX operations uses a stream-cipher scrambler to minimize peak amplitudes
in the frequency spectrum. However, the nature of the stream cipher and MLT-3 encoding is such that long
sequences of consecutive zeros or ones can exist. These unbalanced data patterns produce an
undesirable DC component in the data stream known as ‘baseline wander’.
Baseline wander adversely affects the noise immunity of the receiver, because the ‘baseline’ signal moves
or ‘wanders’ from its nominal DC value. The ICS1893Y-10 uses a unique technique to restore the DC
component ‘lost’ by the medium. As a result, the design is very robust, immune to noise and independent
of the data stream.
ICS1893Y-10 Data Sheet - Release
Copyright © 2004, Integrated Circuit Systems, Inc.
Table
7-16, which minimizes crosstalk and noise in repeater applications.
All rights reserved.
50
Section 4.5, “100Base-TX
Section 5.5, “Twisted-Pair
Chapter 6 Functional Blocks
Operations”.
Interface”.
January, 2004