INT-1532-L-5-L-010 TE Connectivity, INT-1532-L-5-L-010 Datasheet - Page 32

DIGITAL PANEL METER, 4-DIGIT, 57.7V TO 139V / 100V TO 240V

INT-1532-L-5-L-010

Manufacturer Part Number
INT-1532-L-5-L-010
Description
DIGITAL PANEL METER, 4-DIGIT, 57.7V TO 139V / 100V TO 240V
Manufacturer
TE Connectivity
Datasheet

Specifications of INT-1532-L-5-L-010

No. Of Digits / Alpha
4
Meter Function
Digital
Meter Range
0mA To 20mA
Digit Height
96mm
Supply Voltage Range
57.7V To 139V / 100V To 240V
Power Consumption
3W
Rohs Compliant
NA
Specifications
Input
Nominal input voltage:
Max continuous input voltage:
Max short duration input voltage:
System VT ratios (primary):
Nominal input voltage burden:
Nominal input current:
System CT primary values:
Max continuous input current:
Max short duration current input:
Nominal input current burden:
Auxiliary
Standard nominal supply voltage:
AC supply frequency range:
AC supply burden:
Optional auxiliary dc supply:
DC Supply Burden:
Measuring ranges
Voltage:
Current:
Frequency:
Accuracy
Voltage:
Current:
Frequency:
Temperature coefficient:
Update time:
Enclosure
Enclosure style:
Compliant with:
Material:
Terminals:
Dielectric voltage:
Operating temperature:
Storage temperature:
Relative humidity:
Warm-up time:
Shock:
Vibration:
Enclosure:
Dimensions:
Panel cut-out:
57.7 to 346V L-N, 100 to 600V L-L
120% nominal
2 x for 1 second, repeated 10 times at 10
second intervals
400kV or 360MW **
< 0.2VA
5A (1A option)
9999:5A or 9999:1A max 360MW **
120% nominal
20 x for 1 second, repeated 5 times at 5 second
intervals
< 0.6VA
** maximum VT or CT ratios are imited so that
the combination of primary voltage and current
do not exceed 360MW at 120% of relevant input.
100-250V ac or dc
(85-287V ac absolute)
(85-312V dc absolute)
45-66Hz
6VA
12-48V dc (10.2-60V dc Absolute)
6VA
70-120% of nominal (functional 4-120%)
5-120% of nominal
45-66Hz
±0.1% of range ±0.4% of reading
±0.1% of range ±0.4% of reading
0.15% of mid frequency
0.013%/°C typical
500ms display
ANSI C39.1
UL 140758 and IEC 1010 / BSEN 61010-1
Polycarbonate front and base, steel case
Barrier terminal strip 6-32 binding head screw
Withstand test 3.25kV rms 50Hz for 1
minute between all electrical circuits
-20 to +70°C
-30 to +80°C
0-95% non condensing
1 minute
30g in 3 planes
10-15Hz, 1.5mm peak to peak / 15-150Hz @1g
Integrity (front face only) IP54
4.31" high x 4.31" wide x 6.7" deep
109.4mm high x 109.4mm wide x 170.2mm deep
4.06" (103mm) diameter, 4 stud positions
Measurement and Display
Measurement of up to 12 electrical
parameters can be programmed and
displayed on the Integra 0640 unit.
1
2
3
4
System volts
System current
System frequency
Volts L1–N (4-wire only)
Volts L2–N (4-wire only)
Volts L3–N (4-wire only)
Volts L1–L2
Volts L2–L3
Volts L3–L1
Current L1
Current L2
Current L3
31

Related parts for INT-1532-L-5-L-010