AMIS49587C5872G ON Semiconductor, AMIS49587C5872G Datasheet - Page 8

IC MODEM PLC 50/60MHZ 52QFN

AMIS49587C5872G

Manufacturer Part Number
AMIS49587C5872G
Description
IC MODEM PLC 50/60MHZ 52QFN
Manufacturer
ON Semiconductor
Datasheet

Specifications of AMIS49587C5872G

Baud Rates
Selectable
Interface
SCI
Voltage - Supply
3 V ~ 3.6 V
Mounting Type
Surface Mount
Package / Case
52-TQFN Exposed Pad
Maximum Operating Temperature
+ 80 C
Minimum Operating Temperature
- 40 C
Modulation Type
.
Mounting Style
SMD/SMT
Operating Supply Voltage
+ 3 V to 3.6 V
Number Of Transmitters
1
Power Supply Requirement
Single
Package Type
QFN EP
Operating Temperature Classification
Commercial
Mounting
Surface Mount
Pin Count
52
Operating Temperature (min)
-40C
Dual Supply Voltage (typ)
Not RequiredV
Dual Supply Voltage (max)
Not RequiredV
Dual Supply Voltage (min)
Not RequiredV
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Data Format
-
Lead Free Status / Rohs Status
Compliant
RX_OUT
RX_OUT is the output analog pin of the receiver low noise input op- -amp. This op- -amp is in a negative feedback
configuration.
RX_IN
RX_IN is the positive analog input pin of the receiver low noise input op- -amp. Together with RX_OUT and REF_OUT, an
active high pass filter is realized. This filter removes the main frequency (50 or 60 Hz) from the received signal. The filter
characteristics are determined by external capacitors and resistors. A typical application schematic can be found in paragraph
50/60 Hz suppression filter.
M50Hz_IN
M50HZ_IN is the mains frequency analog input pin. The signal is used to detect the zero crossing of the 50 or 60 Hz sine wave.
This information is used, after filtering with the internal PLL, to synchronize frames with the mains frequency. In case of direct
connection to the mains it is advised to use a series resistor of 1 MΩ in combination with two external clamp diodes in order
to limit the current flowing through the internal protection diodes.
RX_DATA
RX_DATA is a 5 V compliant open drain output. An external pull- -up resistor defines the logic high level as illustrated in
Figure 5. A typical value for the pull- -up resistance “R” is 10 kΩ. The signal on this output depends on the status of the data
reception. If AMIS- -49587 waits for configuration RX_DATA outputs a pulse train with a 10 Hz frequency. After
Synchronization Confirm Time out RX_DATA = 0. If AMIS- -49587 is searching for synchronization RX_DATA = 1.
Figure 4. Recommended Layout of the Placement of Decoupling Capacitors for PLCC- -28
Figure 5. Representation of 5V Safe Output
11
10
5
6
7
8
9
C
DREF
V
12 13 14
4
SSD
http://onsemi.com
3
2
15
1
16
28
8
+5V
C DA
17 18
27 26
C DD
R
3,3V SUPPLY
GROUND
25
24
23
22
21
20
19
Output

Related parts for AMIS49587C5872G