AD7356 Analog Devices, AD7356 Datasheet - Page 15

no-image

AD7356

Manufacturer Part Number
AD7356
Description
Differential Input, Dual, Simultaneous Sampling, 5 MSPS, 12-Bit, SAR ADC
Manufacturer
Analog Devices
Datasheet

Specifications of AD7356

Resolution (bits)
12bit
# Chan
2
Sample Rate
5MSPS
Interface
Ser,SPI
Analog Input Type
Diff-Uni
Ain Range
(Vref) p-p,2.048 V p-p
Adc Architecture
SAR
Pkg Type
SOP

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
AD7356BRUZ
Manufacturer:
Artesyn
Quantity:
1 001
Part Number:
AD7356BRUZ
Manufacturer:
ADI
Quantity:
1 000
Part Number:
AD7356BRUZ
Manufacturer:
ADI/亚德诺
Quantity:
20 000
Part Number:
AD7356BRUZ-500RL7
Manufacturer:
AD
Quantity:
2 150
Part Number:
AD7356BRUZ-500RL7
Manufacturer:
ADI/亚德诺
Quantity:
20 000
Part Number:
AD7356BRUZ-RL
Manufacturer:
AD
Quantity:
2 150
Part Number:
AD7356BRUZ-RL
Manufacturer:
ADI
Quantity:
1 000
MODES OF OPERATION
The mode of operation of the AD7356 is selected by controlling
the logic state of the CS signal during a conversion. There are
three possible modes of operation: normal mode, partial power-
down mode, and full power-down mode. After a conversion is
initiated, the point at which CS is pulled high determines which
power-down mode, if any, the device enters. Similarly, if already
in a power-down mode, CS can control whether the device returns
to normal operation or remains in a power-down mode.
These modes of operation are designed to provide flexible
power management options. These options can be chosen to
optimize the power dissipation/throughput rate ratio for the
differing application requirements.
NORMAL MODE
Normal mode is intended for applications needing the fastest
throughput rates because the user does not have to worry about
any power-up times because the AD7356 remains fully powered
at all times. Figure 24 shows the general diagram of the
operation of the AD7356 in normal mode.
The conversion is initiated on the falling edge of CS , as described
in the
fully powered up at all times,
10 SCLK falling edges have elapsed after the falling edge of CS .
If CS is brought high any time after the 10
but before the 14
up; however, the conversion is terminated and SDATA and
SDATA
and access the conversion result for the AD7356, 14 serial clock
cycles are required. The SDATA lines do not return to three-
state after 14 SCLK cycles have elapsed but instead do so when
CS is brought high again. If CS is left low for another two SCLK
cycles, two trailing zeros are clocked out after the data. If CS is
left low for a further 14 SCLK cycles, the result for the other
ADC on board is also accessed on the same SDATA line (see
Figure 31
Once 32 SCLK cycles have elapsed, the SDATA line returns to
three-state on the 32
prior to this, the SDATA line returns to three-state at that point.
Thus, CS may idle low after 32 SCLK cycles until it is brought
high again sometime prior to the next conversion. The bus still
returns to three-state upon completion of the dual result read.
SDATA
SDATA
SCLK
CS
A
B
Serial Interface
B
go back into three-state. To complete the conversion
and the
1
th
Figure 24. Normal Mode Operation
Serial Interface
LEADING ZEROS + CONVERSION RESULT
SCLK falling edge, the part remains powered
nd
section. To ensure that the part remains
SCLK falling edge. If CS is brought high
CS must remain low until at least
section).
10
th
SCLK falling edge
14
A
Rev. A | Page 15 of 20
When a data transfer is complete and SDATA
have returned to three-state, another conversion can be initiated
after the quiet time, t
(assuming the required acquisition time has been allowed).
PARTIAL POWER-DOWN MODE
Partial power-down mode is intended for use in applications in
which slower throughput rates are required. Either the ADC
is powered down between each conversion or a series of
conversions can be performed at a high throughput rate and
the ADC is then powered down between these bursts of several
conversions. It is recommended that the AD7356 not remain
in partial power-down mode for longer than 100 μs. When
the AD7356 is in partial power-down, all analog circuitry is
powered down except for the on-chip reference and reference
buffers.
To enter partial power-down mode, the conversion process
must be interrupted by bringing CS high any time after the
second falling edge of SCLK and before the 10
SCLK, as shown in
in this window of SCLKs, the part enters partial power-down,
the conversion that was initiated by the falling edge of CS is
terminated, and SDATA
If CS is brought high before the second SCLK falling edge, the
part remains in normal mode and does not power down. This
avoids accidental power-down due to glitches on the CS line.
To exit this mode of operation and power up the AD7356 again,
perform a dummy conversion. On the falling edge of CS , the
device begins to power up, and continues to power up as long
as CS is held low until after the falling edge of the 10
The device is fully powered up after approximately 200 ns have
elapsed (or one full conversion) and valid data results from the
next conversion, as shown in
before the second falling edge of SCLK, the AD7356 again goes
into partial power-down. This avoids accidental power-up due
to glitches on the CS line. Although the device may begin to
power up on the falling edge of CS , it powers down again on the
rising edge of CS . If the AD7356 is already in partial power-down
mode and CS is brought high between the second and 10
falling edges of SCLK, the device enters full power-down mode.
SDATA
SDATA
SCLK
CS
A
B
Figure 25. Entering Partial Power-Down Mode
1
Figure 25
2
QUIET
A
, has elapsed by bringing CS low again
and SDATA
. When
Figure 26
CS has been brought high
B
. If
go back into three-state.
10
THREE-STATE
CS is brought high
A
th
and SDATA
falling edge of
1
AD7356
4
th
SCLK.
th
B

Related parts for AD7356