AD7321 Analog Devices, AD7321 Datasheet - Page 29

no-image

AD7321

Manufacturer Part Number
AD7321
Description
500 kSPS, 2-Channel, Software-Selectable, True Bipolar Input, 12-Bit Plus Sign ADC
Manufacturer
Analog Devices
Datasheet

Specifications of AD7321

Resolution (bits)
13bit
# Chan
2
Sample Rate
500kSPS
Interface
Ser,SPI
Analog Input Type
Diff-Uni,SE-Uni
Ain Range
Bip 10V,Bip 2.5V,Bip 5.0V,Uni 10V
Adc Architecture
SAR
Pkg Type
SOP

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
AD7321BRUZ
Manufacturer:
AD
Quantity:
3 100
Part Number:
AD7321BRUZ
Manufacturer:
ADI
Quantity:
2 000
Part Number:
AD7321BRUZ
Manufacturer:
ADI
Quantity:
1 000
Part Number:
AD7321BRUZ
Manufacturer:
Analog Devices Inc
Quantity:
135
Part Number:
AD7321BRUZ
Manufacturer:
ADI/亚德诺
Quantity:
20 000
Part Number:
AD7321BRUZ-REEL7
Manufacturer:
ADI
Quantity:
1 000
AUTOSHUTDOWN MODE
(PM1 = 1, PM0 = 0)
Once the autoshutdown mode is selected, the AD7321 auto-
matically enters shutdown on the 15
autoshutdown mode, all internal circuitry is powered down.
The AD7321 retains information in the registers during
autoshutdown. The track-and-hold is in hold mode during
autoshutdown. On the rising CS edge, the track-and-hold,
which was in hold during shutdown, returns to track as the
AD7321 begins to power up. The power-up from autoshutdown
is 500 μs.
When the control register is programmed to transition to
autoshutdown mode, it does so on the 15
Figure 47 shows the part entering autoshutdown mode. The
AD7321 automatically begins to power up on the CS rising
edge. The t
by bringing the CS signal low, can take place. Once this valid
conversion is complete, the AD7321 powers down again on the
15
keep the part in autoshutdown mode.
AUTOSTANDBY MODE
(PM1 = 0, PM0 =1)
In autostandby mode, portions of the AD7321 are powered
down, but the on-chip reference remains powered up. The
reference bit in the control register should be 1 to ensure that
the on-chip reference is enabled. This mode is similar to
autoshutdown but allows the AD7321 to power up much faster,
which allows faster throughput rates.
th
SDATA
SCLK
SCLK rising edge. The CS signal must remain low again to
DIN
CS
POWER-UP
CONTROL REGISTER IS LOADED ON THE FIRST 15 CLOCKS,
1
is required before a valid conversion, initiated
DATA INTO CONTROL REGISTER
PART ENTERS SHUTDOWN MODE
ON THE 15TH RISING SCLK EDGE
AS PM1 = 1, PM0 = 0
PM1 = 1, PM0 = 0
VALID DATA
th
SCLK rising edge. In
th
SCLK rising edge.
Figure 47. Entering Autoshutdown/Autostandby Mode
15
PART BEGINS TO POWER
UP ON CS RISING EDGE
16
Rev. A | Page 29 of 36
As is the case with autoshutdown mode, the AD7321 enters
standby on the 15
is updated (see Figure 47). The part retains information in the
registers during standby. The AD7321 remains in standby until
it receives a CS rising edge. The ADC begins to power up on the
CS rising edge. On the CS rising edge, the track-and-hold, which
was in hold mode while the part was in standby, returns to track.
The power-up time from standby is 700 ns. The user should
ensure that 700 ns have elapsed before bringing CS low to
attempt a valid conversion. Once this valid conversion is
complete, the AD7321 again returns to standby on the 15
SCLK rising edge. The CS signal must remain low to keep the
part in standby mode.
Figure 47 shows the part entering autoshutdown mode. The
sequence of events is the same when entering autostandby
mode. In Figure 47, the power management bits are configured
for autoshutdown. For autostandby mode, the power
management bits, PM1 and PM0, should be set to 0 and 1,
respectively.
t
POWER-UP
THE PART IS FULLY POWERED UP
ONCE
t
POWER-UP
1
th
SCLK rising edge once the control register
HAS ELAPSED
DATA INTO CONTROL REGISTER
VALID DATA
15
AD7321
16
th

Related parts for AD7321