TLE 8264-2E

Manufacturer Part Number
TLE 8264-2E
Description
Manufacturer
Infineon Technologies
Datasheet

Specifications of TLE 8264-2E

Packages
PG-DSO-36
Transceiver
High Speed CAN ISO 11898 - 5 / 3 x LIN2.0 / J2602
Voltage Regulator Output
2 x 200 mA + 400 mA
Watchdog
Standard and Window Watchdog
Quiescent Current (max.)
28 ?A (typ) Sleep Mode (5V on)
Standby Current
58 ?A (typ) Stop Mode (5V on)
4
4.1
Figure 3
Data Sheet
1st (config1) or 2nd (config3) WD trig
in Normal / Stop / SW Flash mode
1st (config2) or 2nd (config4) WD trig failure
in Normal / Stop / SW Flash mode
Reset clamped LOW (any
failure
Config 1/3:
Detection of falling edge at reset
mode)
undervoltage reset at V
Reset clamped LOW (any
State Machine
Block Description
Power Mode Management
pin (any mode)
(any mode)
Config 2/4:
WD trig
mode)
OR
WD failed
CC1µC
SPI cmd
Release of over temperature at Vcc1
OR
(LH entry condition stored)
CAN, LIN, WK Wake-up
(Wake-up event stored)
act/inact
act/inact
Vcc1
Vcc1
L.H.
L.H.
on
on
SBC SW Flash mode
SBC Restart mode
OR
SPI cmd
Vcc1
waked or off
L.H.
Vcc2/3
Vcc2/3
NOT reset clamped
act
Tx/Rx
NOT undervoltage
LH entry condition
off
on/off
on/off
CAN
WK event stored
condition stored
CAN
SBC Fail-Safe mode
Restart entry
(high or low)
at Vcc1
stored
OR
OR
Vcc2/3
sleep
waked or off
CAN
Reset
off
fixed
Flash
mode
WD
act.
LIN
LIN
sleep
Vcc1
(256ms max after reset relaxation)
inact
L.H.
WD
LIN
on
off
SBC Init mode
First battery connection
act/inact
reset (initiated by SBC )
config0 not active
Reset clamped HIGH during restart / init
Vcc1
L.H.
Vcc2/3
off
Init mode not successful
10
CAN
inact
(POR)
off
SBC Sleep mode
AND
SPI cmd
Reset clamped HIGH during Restart
Vcc1 over temperature shutdown
V
Wakable/
Wake up event
S
Vcc2/3
Config 1/3:
> V
CAN
off
off
UV_ON
inact
conf
WD
LIN
or Init mode
out on V
SPI cmd
Config 2/4:
& Undervoltage time
OR
Wakable/
CC1
act/inact
WD
LIN
Vcc1
off
off
L.H.
on
SBC Normal mode
SPI cmd
Vcc2/3
on/off
SPI cmd
CAN
conf
SPI cmd
act/inact
Condition / event
mode set
mode set
Vcc1
L.H.
on
conf
conf
Vcc1
Vcc1
inact.
SBC action
WD
LIN
L.H.
SBC Factory Flash mode
ext.
L.H.
SBC SW Development
SBC Stop mode
Power mode managment . vsd
First battery connection
SPI cmd
wakable/
Vcc2/3
mode set
mode set
on/off
CAN
Vcc2/3
Rev. 1.0, 2009-03-31
Vcc2/3
config0
mode
(POR)
off
AND
CAN
CAN
off
off
WD trig
TLE8264-2E
State Machine
wakable/
fixed/off
mode set
mode set
WD
LIN
off
WD
LIN
WD
LIN
off
off
WD trig

Related parts for TLE 8264-2E