AD9396/PCB Analog Devices, AD9396/PCB Datasheet - Page 39

no-image

AD9396/PCB

Manufacturer Part Number
AD9396/PCB
Description
Analog/dvi Dual-display Interface
Manufacturer
Analog Devices
Datasheet
2-WIRE SERIAL CONTROL PORT
A 2-wire serial interface control is provided in the AD9396.
Up to two AD9396 devices can be connected to the 2-wire serial
interface, with a unique address for each device.
The 2-wire serial interface comprises a clock (SCL) and a
bidirectional data (SDA) pin. The analog flat panel interface
acts as a slave for receiving and transmitting data over the serial
interface. When the serial interface is not active, the logic levels
on SCL and SDA are pulled high by external pull-up resistors.
Data received or transmitted on the SDA line must be stable for
the duration of the positive-going SCL pulse. Data on SDA must
change only when SCL is low. If SDA changes state while SCL is
high, the serial interface interprets that action as a start or stop
sequence.
There are six components to serial bus operation:
When the serial interface is inactive (SCL and SDA are high)
communications are initiated by sending a start signal. The start
signal is a high-to-low transition on SDA while SCL is high.
This signal alerts all slave devices that a data transfer sequence
is coming.
The first eight bits of data transferred after a start signal
comprise a 7 bit slave address (the first 7 bits) and a single R/ W
bit (the 8th bit). The R/ W bit indicates the direction of data
transfer, read from (1) or write to (0) the slave device. If the
transmitted slave address matches the address of the device
(set by the state of the SA0 input pin, as shown in Table 21), the
AD9396 acknowledges by bringing SDA low on the 9th SCL
pulse. If the addresses do not match, the AD9396 does not
acknowledge.
Table 21. Serial Port Addresses
Bit 7
A
1
6
(MSB)
Start signal
Slave address byte
Base register address byte
Data byte to read or write
Stop signal
Acknowledge (Ack)
SDA
SCL
Bit 6
A
0
5
t
STAH
t
BUFF
Bit 5
A
0
4
Bit 4
A
1
3
t
DHO
Bit 3
A
1
2
t
DAL
Bit 2
A
0
1
Figure 16. Serial Port Read/Write Timing
t
DAH
t
DSU
Bit 1
A
0
0
Rev. 0 | Page 39 of 48
Data Transfer via Serial Interface
For each byte of data read or written, the MSB is the first bit of
the sequence.
If the AD9396 does not acknowledge the master device during a
write sequence, the SDA remains high so the master can gener-
ate a stop signal. If the master device does not acknowledge the
AD9396 during a read sequence, the AD9396 interprets this as
end of data. The SDA remains high, so the master can generate
a stop signal.
Writing data to specific control registers of the AD9396 requires
that the 8-bit address of the control register of interest be writ-
ten after the slave address has been established. This control
register address is the base address for subsequent write opera-
tions. The base address auto-increments by one for each byte of
data written after the data byte intended for the base address. If
more bytes are transferred than there are available addresses,
the address does not increment and remains at its maximum
value. Any base address higher than the maximum value does
not produce an acknowledge signal.
Data are read from the control registers of the AD9396 in a
similar manner. Reading requires two data transfer operations:
To terminate a read/write sequence to the AD9396, a stop signal
must be sent. A stop signal comprises a low-to-high transition
of SDA while SCL is high.
A repeated start signal occurs when the master device driving
the serial interface generates a start signal without first genera-
ting a stop signal to terminate the current communication. This
is used to change the mode of communication (read, write)
between the slave and master without releasing the serial
interface lines.
The base address must be written with the R/ W bit of the
slave address byte low to set up a sequential read
operation.
Reading (the R/ W bit of the slave address byte high) begins
at the previously established base address. The address of
the read register auto-increments after each byte is
transferred.
t
STASU
t
STOSU
AD9396

Related parts for AD9396/PCB