ep2c35 Altera Corporation, ep2c35 Datasheet - Page 88

no-image

ep2c35

Manufacturer Part Number
ep2c35
Description
Cyclone Ii Device Family Data Sheet
Manufacturer
Altera Corporation
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
ep2c35F484
Manufacturer:
ALTERA
Quantity:
1 235
Part Number:
ep2c35F484
Manufacturer:
ALTERA
0
Part Number:
ep2c35F48418NK
Manufacturer:
ALTERA
0
Part Number:
ep2c35F484C6
Manufacturer:
Altera
Quantity:
10 000
Part Number:
ep2c35F484C6
Manufacturer:
ALTERA
0
Part Number:
ep2c35F484C6N
Manufacturer:
ALTERA
Quantity:
591
Part Number:
ep2c35F484C6N
Manufacturer:
Altera
Quantity:
10 000
Part Number:
ep2c35F484C6N
Manufacturer:
ALTERA/阿尔特拉
Quantity:
20 000
Company:
Part Number:
ep2c35F484C6N
Quantity:
1 000
Part Number:
ep2c35F484C7
Manufacturer:
ALTERA
Quantity:
300
Part Number:
ep2c35F484C7
Manufacturer:
ALTERA/阿尔特拉
Quantity:
20 000
Part Number:
ep2c35F484C7ES
Manufacturer:
OKI
Quantity:
45 725
Part Number:
ep2c35F484C7ES
Manufacturer:
ALTERA/阿尔特拉
Quantity:
20 000
Part Number:
ep2c35F484C7N
Manufacturer:
ALTERA
Quantity:
465
Power-On Reset Circuitry
4–6
Cyclone II Device Handbook, Volume 1
For Cyclone II devices, wake-up time consists of power-up, POR,
configuration, and initialization. The device must properly go through all
four stages to configure correctly and begin operation. You can calculate
wake-up time using the following equation:
Figure 4–3
Figure 4–3. Cyclone II Wake-Up Time
Note to
(1)
The V
characteristics and the power supply used in your system. The fast-on
devices require a maximum V
POR time of 12 ms.
Configuration time will depend on the configuration mode chosen and
the configuration file size. You can calculate configuration time by
multiplying the number of bits in the configuration file with the period of
the configuration clock. For fast configuration times, you should use
Passive Serial (PS) configuration mode with maximum DCLK frequency
of 100 MHz. In addition, you can use compression to reduce the
configuration file size and speed up the configuration time. The t
or t
1
Wake-Up Time = V
V
CC
Minimum
CD2UMC
V
CC
CC
Figure
ramp must be monotonic.
ramp time and POR time will depend on the device
For more information on the t
to the Configuring Cyclone II Devices chapter in the Cyclone II
Device Handbook.
illustrates the components of wake up time.
parameters will determine the initialization time.
Voltage
V
CC
Time
4–3:
Ramp
CC
Ramp Time + POR Time + Configuration Time + Initialization Time
POR Time
CC
ramp time of 2 ms and have a maximum
Configuration Time
CD2UM
or t
CD2UMC
Altera Corporation
parameters, refer
Initialization
Time
February 2007
CD2UM
Mode
User
Time

Related parts for ep2c35