ep2c35 Altera Corporation, ep2c35 Datasheet - Page 89

no-image

ep2c35

Manufacturer Part Number
ep2c35
Description
Cyclone Ii Device Family Data Sheet
Manufacturer
Altera Corporation
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
ep2c35F484
Manufacturer:
ALTERA
Quantity:
1 235
Part Number:
ep2c35F484
Manufacturer:
ALTERA
0
Part Number:
ep2c35F48418NK
Manufacturer:
ALTERA
0
Part Number:
ep2c35F484C6
Manufacturer:
Altera
Quantity:
10 000
Part Number:
ep2c35F484C6
Manufacturer:
ALTERA
0
Part Number:
ep2c35F484C6N
Manufacturer:
ALTERA
Quantity:
591
Part Number:
ep2c35F484C6N
Manufacturer:
Altera
Quantity:
10 000
Part Number:
ep2c35F484C6N
Manufacturer:
ALTERA/阿尔特拉
Quantity:
20 000
Company:
Part Number:
ep2c35F484C6N
Quantity:
1 000
Part Number:
ep2c35F484C7
Manufacturer:
ALTERA
Quantity:
300
Part Number:
ep2c35F484C7
Manufacturer:
ALTERA/阿尔特拉
Quantity:
20 000
Part Number:
ep2c35F484C7ES
Manufacturer:
OKI
Quantity:
45 725
Part Number:
ep2c35F484C7ES
Manufacturer:
ALTERA/阿尔特拉
Quantity:
20 000
Part Number:
ep2c35F484C7N
Manufacturer:
ALTERA
Quantity:
465
Conclusion
Document
Revision History
Altera Corporation
February 2007
February 2007
v3.1
July 2005 v2.0
February 2005
v1.1
June 2004 v1.0
Table 4–1. Document Revision History
Document
Version
Date &
Updated technical content throughout.
Removed ESD section.
Added document to the Cyclone II Device Handbook.
Added document revision history.
Updated
section.
Updated
Added footnote to
If you cannot meet the maximum V
use an external component to hold nCONFIG low until the power supplies
have reached their minimum recommend operating levels. Otherwise,
the device may not properly configure and enter user mode.
Cyclone II devices are hot socketable and support all power-up and
power-down sequences with the one requirement that V
be powered up and down within 100 ms of each other to keep the I/O
pins from driving out. Cyclone II devices do not require any external
devices for hot socketing and power sequencing.
Table 4–1
“I/O Pins Remain Tri-Stated during Power-Up”
“Power-On Reset Circuitry”
Figure
Changes Made
shows the revision history for this document.
4–3.
section.
CC
Cyclone II Device Handbook, Volume 1
ramp time requirement, you must
Hot Socketing & Power-On Reset
Specified V
supplies must be GND
when "not powered".
Added clarification about
input-tristate behavior.
Added infomation on V
monotonic ramp.
Summary of Changes