sc16c852viet NXP Semiconductors, sc16c852viet Datasheet - Page 28

no-image

sc16c852viet

Manufacturer Part Number
sc16c852viet
Description
Sc16c852v 1.8 V Dual Uart, 5 Mbit/s Max. With 128-byte Fifos, Infrared Irda , And Xscale Vlio Bus Interface
Manufacturer
NXP Semiconductors
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
SC16C852VIET
Manufacturer:
NXP
Quantity:
1 469
Part Number:
sc16c852viet,115
Manufacturer:
NXP Semiconductors
Quantity:
10 000
Part Number:
sc16c852viet,118
Manufacturer:
NXP Semiconductors
Quantity:
10 000
Part Number:
sc16c852viet,151
Manufacturer:
LT
Quantity:
595
Part Number:
sc16c852viet,151
Manufacturer:
NXP Semiconductors
Quantity:
10 000
Part Number:
sc16c852viet,157
Manufacturer:
NXP Semiconductors
Quantity:
10 000
NXP Semiconductors
SC16C852V_4
Product data sheet
7.5 Line Control Register (LCR)
The Line Control Register is used to specify the asynchronous data communication
format. The word length, the number of stop bits, and the parity are selected by writing the
appropriate bits in this register.
Table 16.
Table 17.
Table 18.
Table 19.
Bit
7
6
5:3
2
1:0
LCR[5]
X
X
0
0
1
LCR[2]
0
1
1
LCR[1]
0
0
1
1
Symbol
LCR[7]
LCR[6]
LCR[5:3]
LCR[2]
LCR[1:0]
LCR[4]
X
0
1
0
1
Line Control Register bits description
LCR[5:3] parity selection
LCR[2] stop bit length
LCR[1:0] word length
Word length (bits)
5, 6, 7, 8
5
6, 7, 8
LCR[0]
0
1
0
1
Dual UART with 128-byte FIFOs, IrDA, and XScale VLIO bus interface
LCR[3]
0
1
1
1
1
Description
Divisor latch enable. The internal baud rate counter latch and Enhanced
Feature mode enable.
Set break. When enabled, the Break control bit causes a break condition to
be transmitted (the TX output is forced to a logic 0 state). This condition
exists until disabled by setting LCR[6] to a logic 0.
Programs the parity conditions (see
Stop bits. The length of stop bit is specified by this bit in conjunction with the
programmed word length (see
Word length bits 1, 0. These two bits specify the word length to be
transmitted or received (see
Rev. 04 — 14 January 2008
logic 0 = divisor latch disabled (normal default condition)
logic 1 = divisor latch enabled
logic 0 = no TX break condition (normal default condition)
logic 1 = forces the transmitter output (TX) to a logic 0 for alerting the
remote receiver to a line break condition
logic 0 or cleared = default condition
logic 0 or cleared = default condition
Parity selection
no parity
odd parity
even parity
forced parity ‘1’
forced parity ‘0’
Stop bit length (bit times)
1
1
2
Word length (bits)
5
6
7
8
1
2
Table
Table
19).
Table
18).
17).
SC16C852V
© NXP B.V. 2008. All rights reserved.