sdc40b Yamatake Corporation, sdc40b Datasheet - Page 5

no-image

sdc40b

Manufacturer Part Number
sdc40b
Description
Digital Indicating Controller
Manufacturer
Yamatake Corporation
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
sdc40b5G4AS09200
Manufacturer:
AZBIL/YAMATAKE
Quantity:
1 000
Output processing
block
Indications and
settings
Modes
Communications
Digital output
(DO1 to DO8)
Display panel 1
Display panel 2
Display panel 3
LED bar display
Status display
Operation keys
Loader connecting port
Normal operating mode
Emergency operating
mode
Communications
system
Interface system
Display characters
Isolation
Note 1 : RS-485 communications can be performed by connecting to a computer equipped with an RS-485 interface or
Yamatake MX200, MA500 AH (DK link II DIM) or CMA50 controllers.
D01
D02
D03
D04
to
D08
Green 5-digit, 7-segment LED
This panel normally displays values. Item codes are displayed in control data setting mode and
alarm codes are displayed when alarms are generated.
Orange 5-digit, 7-segment LED
This panel normally displays SP values. Set values are displayed in control data setting mode.
Orange 2-digit, 7-segment LED
This panel displays the difference between LSP and RSP values in normal indicating mode when
display panel 2 shows SP values. In control data setting mode, item codes are displayed.
12 green and amber LEDs
Analog monitor (includes control output) which doubles as a digital monitor.
18 LEDs
SP, LCK, OUT, CH1 (PID computational unit 1), CH2 (PID computational unit 2), FLW (follow mode),
AUT (auto mode), MAN (manual mode), CAS (cascade mode), IM (interlock manual mode),
AT (auto-tuning), FZY (during fuzzy switching), OUT1, OUT2, OUT (bar graph control output),
UF1,UF2, UF3 (user defined)
13 rubber keys (of which two are user definable)
1 (dedicated cable with stereo miniplugs)
Auto mode
Manual mode
Cascade mode PID computational units control cascade settings (RSP).
Follow mode
Interlock manual mode: This mode is activated when an analog overflow, computational overflow or
Communications
standard
Network
Data flow
Synchronization
Transmission
system
Data line
Signal line
Transmission
rate
Transmission
distance
Misc
Char. bit
count
Data length
Input and output are completely isolated.
Format
SPST relay
contact
SPST relay
contact
Open
collector
PID computational units control constants (LSP).
MAN computational units output manual settings. (However, only one MAN
computational unit can be used.)
Only PID computational units perform integral operations.
MAN computational units outputs follow inputs to the SDC40B.
Multidrop (SDC40B provided with only
slave node functionality) 1 to 16 units
or less (DIM), 1 to 31 units or less
(CMA, SCM)
Half duplex
Start-stop synchronization
Balanced (differential)
Bit serial
5 transmit/receive lines (3-wire
connection is also possible.)
4800, 9600bps
500m max. (total) (300m for MA500DM
connection)
Comforms to RS-485 standard
11 bits per character
1 start bit, even parity, 1 stop bit; or
1 start bit, no parity, and 2 stop bits
8 bits
5
computational overload is detected
Electric rating: 250Vac, 30Vdc, 1A resistive load
Mechanical life: 20,000,000 repetitions
Electrical life: 100,000 repetitions (at rated capacity)
Minimum switching voltage: 10V
Minimum switching current: 10mA
Electric rating: 250Vac, 30Vdc, 2A resistive load
Mechanical life: 50,000,000 repetitions
Electrical life: 100,000 repetitions (at rated capacity)
Minimum switching voltage: 10V
Minimum switching current: 10mA
External supply voltage: 10 to 29Vdc
Maximum load current: 70mA per point
Leakage current when off: 0.1mA
RS-485
Point-to-point (SDC40B provided with
only slave node functionality)
Half duplex
Start-stop synchronization
Unbalanced
Bit serial
3 transmit /receive lines
4800, 9600bps
15m max.
Comforms to RS-232C standard
11 bits per character
1 start bit, even parity, 1 stop bit; or
1 start bit, no parity, and 2 stop bits
8 bits
RS-232C