sdc40b Yamatake Corporation, sdc40b Datasheet - Page 6

no-image

sdc40b

Manufacturer Part Number
sdc40b
Description
Digital Indicating Controller
Manufacturer
Yamatake Corporation
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
sdc40b5G4AS09200
Manufacturer:
AZBIL/YAMATAKE
Quantity:
1 000
General
specifications
Standard
accessories
Related
Publications
Memory backup
Rated power voltage
Allowable power
supply voltage
Power consumption
Power switching
inrush current
Power ON operation
Allowable transient
power loss
Power failure recovery
operations
Insulation resistance
Dielectric strength
Standard conditions
Operating conditions
Shipping and
storage conditions
Materials of mask and case
Colors of mask and case
Installation
Weight (Mass)
Unit indicating label
Mounting bracket
User’s manual:
Basic Operations
User’s manual:
Computational Functions
User’s manual:
CPL Communication
Functions
Parts name
User settings (design data and control data): Non-volatile semiconductor memory (EEPROM) Mode,
local SP, control output (AO1) and hold computations: RAM backed up by super-capacitor (stored for
24 hours)
AC model
DC model
AC model
DC model
AC model
DC model
15A max. for (under operating conditions)
Note: When starting up a number of SDC 40B, simultaneously, ensure ample power is supplied
Reset time: 15 sec. max. (time until normal operation possible under normal operating conditions)
AC model
DC model
Hot start or cold start selectable (see below)
Selection
Hot start
Cold start
Min. 20MΩ or more between power terminal 1 or 2 and ground terminal 3 (using a 500Vdc megger).
AC model
DC model
Ambient temperature
Ambient humidity
Rated power voltage
Power frequency
Vibration resistance
Impact resistance
Mounting angle
Ambient temperature range
Ambient humidity range
Rated power voltage
Power frequency
Vibration resistance
Impact resistance
Mounting angle
Installation mode
Application standards
Over-voltage category
Pollution degree
Altitude
Ambient temperature range
Ambient humidity range
Vibration resistance
Impact resistance
Package drop test
Mask: Multilon
Mask: dark gray
Specially designed mounting bracket
Approx. 900g
N-3132
81405411-001
CP-UM-1679E
CP-UM-1680E
CP-UM-1683E
Parts number
or stagger their startup times. Otherwise the controllers may not start normally due inrush
current induced-voltage drop. Voltage must stabilize within 2 seconds after power on.
During normal operation Hot start
During failure
N/A not applicable
1500Vac 50/60 Hz for 1min across power terminal and ground terminal
1500Vac 50/60 Hz for 1min across relay output and gruond terminal
500Vac 50/60 Hz for 1min across non-power terminal and ground terminal
500Vac 50/60 Hz for 1min across isolated terminal
500Vac 50/60 Hz for 1min across power terminal and ground terminal
1500Vac 50/60 Hz for 1min across relay output and gruond terminal
500Vac 50/60 Hz for 1min across non-power terminal and ground terminal
500Vac 50/60 Hz for 1min across isolated terminal
100 to 240Vac 50/60 hz
24Vdc
90 to 264Vdc 50/60 Hz
21.6 to 26.4Vdc
30 VA max.
12W max.
20ms min. (under operating conditions)
No power failure allowed.
RAM backup
Case: Polycarbonate
Case: Light gray
Quantity
6
1
2
1
23 ± 2°C
60 ± 5% RH
AC model
DC model
AC model
0m/s
0m/s
Reference plane (vertical) ± 3°
0 to 50°C
10 to 90% RH (non-condensing)
AC model: 100 to 240Vac
AC model: 50 ± 2Hz or 60 ± 2Hz
0 to 1.96m/s
0 to 9.81m/s
Reference plane (vertical) ±10°
Parmanently connected type controller, indoor installation, panel-mounted
EN61010-1, EN 61326 (CE statement)
Category II (IEC60364-4-443, IE60664-1)
2
2000m max.
-20 to 70°C
10 to 95% RH (non-condensing)
0 to 4.90m/s
0 to 4.90m/s
Drop height: 90cm (1 angle, 3 edges and 6 planes; free fall)
2
2
recovery process
Cold start
Actual outage
Options
2
2
2
2
(10 to 60Hz for 2 hours each in X, Y and Z directions)
(3 times vertically)
105Vac ± 1%
24Vdc ± 5%
50 ± 1Hz or 60 ± 1Hz
Hard dust-proof cover set
Soft dust-proof cover set
Terminal cover set
Smart Loader package
Before outage
Preset mode
Mode
DC model: 24Vdc
Parts name
Before outage
Preset LSP
Description
Local SP
81446083-001
81 446087-001
81446084-001
SLPC4B-001H
Parts number
Before outage
Preset value
Controloutput (AO1)

Related parts for sdc40b