Page 1
... ELECTROSTATIC SENSITIVE DEVICE OBSERVE HANDLING PRECAUTIONS RoHS Compliance , 440-520MHz 7.0W 7.2V, 2 Stage Amp. For PORTABLE RADIO DESCRIPTION The RA07M4452MSA is a 7-watt RF MOSFET Amplifier Module for 7.2-volt portable radios that operate in the 440- to 520-MHz range. The battery can be connected directly to the drain of the enhancement-mode MOSFET transistors. Without the gate ...
Page 2
... V =4.0-9.2V, P =25-70mW, P < out Load VSWR=8:1 V =9.2V, P =50mW, P =7W (V control out GG Load VSWR=20:1 MITSUBISHI ELECTRIC 2/8 MITSUBISHI RF POWER MODULE RA07M4452MSA RATING 9 -30 to +90 -40 to +110 MIN TYP MAX 440 520 7.0 40 -25 -30 4:1 1 control parasitic oscillation No degradation or destroy ...
Page 3
... OUTPUT POWER and DRAIN CURRENT 4.0 16 3.5 14 3.0 12 2 out 1.5 6 1.0 4 0 (V) DD MITSUBISHI ELECTRIC 3/8 MITSUBISHI RF POWER MODULE RA07M4452MSA HARMONICS versus FREQUENCY nd V =7. =3.5V GG Pin=50mW 440 460 480 500 520 540 FREQUENCY f(MHz) 5.0 f=490MHz 4.5 V =7. out 4 ...
Page 4
... DD 3.5 14 3 2.0 P out 1.5 1.0 0.5 0.0 3.0 4.0 (V) GG 3.5 3.0 2 2.0 P out 1.5 1.0 0.5 0.0 3.0 4.0 (V) GG MITSUBISHI ELECTRIC 4/8 MITSUBISHI RF POWER MODULE RA07M4452MSA OUTPUT POWER and DRAIN CURRENT versus GATE VOLTAGE f=490MHz P =50mW IN V =7. out 1.0 2.0 3.0 4.0 GATE VOLTAGE V (V) GG 3.5 3.0 2.5 2.0 1.5 1.0 0.5 0.0 5 Feb 2008 ...
Page 5
... ELECTROSTATIC SENSITIVE DEVICE OBSERVE HANDLING PRECAUTIONS OUTLINE DRAWING (mm) RA07M4452MSA RoHS COMPLIANCE MITSUBISHI ELECTRIC 5/8 MITSUBISHI RF POWER MODULE RA07M4452MSA 5 Feb 2008 ...
Page 6
... Meter =50Ω G Directional Coupler Power DC Power Supply V Supply MITSUBISHI ELECTRIC 6/8 MITSUBISHI RF POWER MODULE RA07M4452MSA Spectrum 5 Analyzer =50Ω L Directional Attenuator Coupler + - Input (P 2 Gate Voltage (V 3 Drain Voltage ( Output ( Ground (Case) 5 Feb 2008 ...
Page 7
... R I =40% th(ch-case (°C/W) (A) 5.4 0.69 2.9 2. case =7.0W, the required thermal resistance R out MITSUBISHI ELECTRIC 7/8 MITSUBISHI RF POWER MODULE RA07M4452MSA V DD (V) 7 are: DD out in th(ch-case) + 16.3 °C case + 36.2 °C case ) below 90°C. For an ambient case = ( (case-air) case air / η ...
Page 8
... Remember to give due consideration to safety when making your circuit designs, with appropriate measures such as (i) placement of substitutive, auxiliary circuits, (ii) use of non-flammable material, or (iii) prevention against any malfunction or mishap. RA07M4452MSA RoHS COMPLIANCE =3.5V (maximum), the nominal output power becomes available. GG Keep safety first in your circuit designs! MITSUBISHI ELECTRIC 8/8 MITSUBISHI RF POWER MODULE RA07M4452MSA 5 Feb 2008 ...