C8051F962-A-GM Silicon Labs, C8051F962-A-GM Datasheet - Page 280

no-image

C8051F962-A-GM

Manufacturer Part Number
C8051F962-A-GM
Description
8-bit Microcontrollers - MCU 128KB, DC-DC, AES DQFN76
Manufacturer
Silicon Labs
Datasheet

Specifications of C8051F962-A-GM

Rohs
yes
Core
8051
Processor Series
C8051
Data Bus Width
8 bit
Maximum Clock Frequency
25 MHz
Program Memory Size
128 KB
Data Ram Size
8448 B
On-chip Adc
Yes
Operating Supply Voltage
2.5 V to 3.3 V
Operating Temperature Range
- 40 C to + 85 C
Package / Case
DQFN-76
Mounting Style
SMD/SMT
Number Of Programmable I/os
57
Number Of Timers
4
C8051F96x
22.2. Power-Fail Reset
C8051F96x devices have two Active Mode Supply Monitors that can hold the system in reset if the supply
voltage drops below V
. The first of the two identical supply monitors is connected to the output of the
RST
supply select switch (which chooses the VBAT or VDC pin as the source of the digital supply voltage) and
is enabled and selected as a reset source after each power-on or power-fail reset. This supply monitor will
be referred to as the digital supply monitor. The second supply monitor is connected directly to the VBAT
pin an is disabled after each power-on or power-fail reset. This supply monitor will be referred to as the
analog supply monitor. The analog supply monitor should be enabled any time the supply select switch is
set to the VDC pin to ensure that the VBAT supply does not drop below V
.
RST
When enabled and selected as a reset source, any power down transition or power irregularity that causes
the monitored supply voltage to drop below V
will cause the RST pin to be driven low and the CIP-51
RST
will be held in a reset state (see Figure 22.2). When the supply voltage returns to a level above V
, the
RST
CIP-51 will be released from the reset state.
After a power-fail reset, the PORSF flag reads 1, the contents of RAM invalid, and the digital supply moni-
tor is enabled and selected as a reset source. The enable state of either supply monitor and its selection as
a reset source is only altered by power-on and power-fail resets. For example, if the supply monitor is de-
selected as a reset source and disabled by software, then a software reset is performed, the supply moni-
tor will remain disabled and de-selected after the reset.
In battery-operated systems, the contents of RAM can be preserved near the end of the battery’s usable
life if the device is placed in Sleep Mode prior to a power-fail reset occurring. When the device is in Sleep
Mode, the power-fail reset is automatically disabled, both active mode supply monitors are turned off, and
the contents of RAM are preserved as long as the supply does not fall below V
. A large capacitor can
POR
be used to hold the power supply voltage above V
while the user is replacing the battery. Upon waking
POR
from Sleep mode, the enable and reset source select state of the V
supply monitor are restored to the
DD
value last set by the user.
To allow software early notification that a power failure is about to occur, the VDDOK bit is cleared when
the supply falls below the V
threshold. The VDDOK bit can be configured to generate an interrupt.
WARN
Each of the active mode supply montiors have their independent VDDOK and V
flags. See Section
WARN
“17. Interrupt Handler” on page 232 for more details.
Important Note: To protect the integrity of Flash contents, the active mode supply monitor(s) must be
enabled and selected as a reset source if software contains routines which erase or write Flash
memory. If the digital supply monitor is not enabled, any erase or write performed on Flash memory will
cause a Flash Error device reset.
280
Rev. 0.5