AT45DB081D-SSU-2.5 Atmel, AT45DB081D-SSU-2.5 Datasheet - Page 17

IC FLASH 8MBIT 50MHZ 8SOIC

AT45DB081D-SSU-2.5

Manufacturer Part Number
AT45DB081D-SSU-2.5
Description
IC FLASH 8MBIT 50MHZ 8SOIC
Manufacturer
Atmel
Datasheet

Specifications of AT45DB081D-SSU-2.5

Format - Memory
FLASH
Memory Type
DataFLASH
Memory Size
8M (4096 pages x 264 bytes)
Speed
50MHz
Interface
SPI, RapidS
Voltage - Supply
2.5 V ~ 3.6 V
Operating Temperature
-40°C ~ 85°C
Package / Case
8-SOIC (3.9mm Width)
Architecture
Sectored
Interface Type
SPI
Supply Voltage (max)
3.6 V
Supply Voltage (min)
2.5 V
Maximum Operating Current
15 mA
Mounting Style
SMD/SMT
Organization
64 KB x 16
Lead Free Status / RoHS Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
AT45DB081D-SSU-2.5
Manufacturer:
ATMEL/爱特梅尔
Quantity:
20 000
10. Security Features
10.1
Figure 10-1. Sector Lockdown
3596M–DFLASH–5/10
Sector Lockdown
CS
SI
Each transition
represents 8 bits
The device incorporates a Sector Lockdown mechanism that allows each individual sector to be
permanently locked so that it becomes read only. This is useful for applications that require the
ability to permanently protect a number of sectors against malicious attempts at altering program
code or security information. Once a sector is locked down, it can never be erased or pro-
grammed, and it can never be unlocked.
To issue the Sector Lockdown command, the CS pin must first be asserted as it would be for
any other command. Once the CS pin has been asserted, the appropriate 4-byte opcode
sequence must be clocked into the device in the correct order. The 4-byte opcode sequence
must start with 3DH and be followed by 2AH, 7FH, and 30H. After the last byte of the command
sequence has been clocked in, then three address bytes specifying any address within the sec-
tor to be locked down must be clocked into the device. After the last address bit has been
clocked in, the CS pin must then be deasserted to initiate the internally self-timed lockdown
sequence.
The lockdown sequence should take place in a maximum time of t
Register will indicate that the device is busy. If the device is powered-down before the comple-
tion of the lockdown sequence, then the lockdown status of the sector cannot be guaranteed. In
this case, it is recommended that the user read the Sector Lockdown Register to determine the
status of the appropriate sector lockdown bits or bytes and reissue the Sector Lockdown com-
mand if necessary.
Table 10-1.
Opcode
Command
Sector Lockdown
Byte 1
Opcode
Byte 2
Sector Lockdown
Opcode
Byte 3
Opcode
Byte 4
Byte 1
3DH
Address
Bytes
Byte 2
2AH
Address
Bytes
Atmel AT45DB081D
P
, during which time the Status
Address
Byte 3
Bytes
7FH
Byte 4
30H
17