SA56004EDP,118 NXP Semiconductors, SA56004EDP,118 Datasheet - Page 16

IC TEMP SENSOR 8-TSSOP

SA56004EDP,118

Manufacturer Part Number
SA56004EDP,118
Description
IC TEMP SENSOR 8-TSSOP
Manufacturer
NXP Semiconductors
Datasheet

Specifications of SA56004EDP,118

Package / Case
8-TSSOP
Output Type
I²C™/SMBus™
Function
Temp Monitoring System (Sensor)
Topology
ADC (Sigma Delta), Multiplexer, Register Bank
Sensor Type
External & Internal
Sensing Temperature
-40°C ~ 125°C, External Sensor
Output Alarm
Yes
Output Fan
Yes
Voltage - Supply
3 V ~ 3.6 V
Operating Temperature
-40°C ~ 125°C
Mounting Type
Surface Mount
Supply Voltage (max)
5.5 V
Supply Voltage (min)
3 V
Maximum Operating Temperature
+ 125 C
Minimum Operating Temperature
- 40 C
Supply Current
1 mA
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
For Use With
568-3615 - DEMO BOARD I2C
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
568-3338-2
935274567118
SA56004EDP-T
NXP Semiconductors
SA56004X_5
Product data sheet
7.9.3 Fault Queue
To suppress erroneous ALERT or T_CRIT triggering, the SA56004X implements a Fault
Queue for both local and remote channel. The Fault Queue insures a temperature
measurement is genuinely beyond a HIGH, LOW or T_CRIT setpoint by not triggering
until three consecutive out-of-limit measurements have been made. The fault queue
defaults OFF upon POR and may be activated by setting bit 0 in the Configuration register
(address 09h) to logic 1.
Fig 8.
Event C: The Status register bit 1 (RCRIT) is reset by a read of the Status register (in
the interrupt mode).
Event A: The remote temperature has exceeded the Remote HIGH setpoint.
Event B: Three consecutive over limit measurements have been made exceeding the
Remote HIGH setpoint; the ALERT output is activated (goes LOW). By now, the remote
temp has exceeded the Remote T_CRIT setpoint (RCS).
Event C: Three consecutive over limit measurements have been made exceeding RCS;
the T_CRIT output is activated (goes LOW).
Event D: The remote temperature falls below the RCS
Event E: The ALERT output is de-activated (goes HIGH) after a below_high_limit
temperature measurement is completed.
remote HIGH setpoint
remote LOW setpoint
Remark: All events indicate the completion of a conversion.
Fault queue remote HIGH and LOW and T_CRIT, T_CRIT hysteresis setpoint
response (comparator mode)
T_CRIT output
ALERT output
RCS
events
RCS
TH
Rev. 05 — 22 May 2008
A
Digital temperature sensor with overtemperature alarms
B
C
remote temperature
D
E
F
TH setpoint.
G
SA56004X
H
© NXP B.V. 2008. All rights reserved.
002aad218
I
16 of 36

Related parts for SA56004EDP,118