Specifications of DS1825U+

Function
Thermometer, Thermostat
Topology
Register Bank, Scratchpad
Sensor Type
Internal
Sensing Temperature
-55°C ~ 125°C
Output Type
Digital
Output Alarm
Yes
Output Fan
No
Voltage - Supply
3 V ~ 3.7 V
Operating Temperature
-55°C ~ 125°C
Mounting Type
Surface Mount
Package / Case
8-MSOP, Micro8™, 8-uMAX, 8-uSOP,
Temperature Threshold
Programmable
Full Temp Accuracy
+/- 0.5 C
Digital Output - Bus Interface
1-Wire
Digital Output - Number Of Bits
9 bit to 12 bit
Supply Voltage (max)
3.7 V
Supply Voltage (min)
3 V
Maximum Operating Temperature
+ 125 C
Minimum Operating Temperature
- 55 C
Supply Current
1.5 mA
Ic Output Type
Digital
Sensing Accuracy Range
± 0.5°C
Supply Voltage Range
3V To 3.7V
Resolution (bits)
12bit
Sensor Case Style
µSOP
No. Of Pins
8
Accuracy %
0.5°C
Rohs Compliant
Yes
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
1-Wire SIGNALING
The DS1825 uses a strict 1-Wire communication protocol to insure data integrity. Several signal types are defined
by this protocol: reset pulse, presence pulse, write 0, write 1, read 0, and read 1. All of these signals, with the
exception of the presence pulse, are initiated by the bus master.
INITIALIZATION PROCEDURE: RESET AND PRESENCE PULSES
All communication with the DS1825 begins with an initialization sequence that consists of a reset pulse from the
master followed by a presence pulse from the DS1825. This is illustrated in Figure 13. When the DS1825 sends the
presence pulse in response to the reset, it is indicating to the master that it is on the bus and ready to operate.
During the initialization sequence the bus master transmits (T
minimum of 480ms. The bus master then releases the bus and goes into receive mode (R
released, the 5k pullup resistor pulls the 1-Wire bus high. When the DS1825 detects this rising edge, it waits 15–
60ms and then transmits a presence pulse by pulling the 1-Wire bus low for 60–240ms.
READ/WRITE TIME SLOTS
The bus master writes data to the DS1825 during write time slots and reads data from the DS1825 during read time
slots. One bit of data is transmitted over the 1-Wire bus per time slot.
WRITE TIME SLOTS
There are two types of write time slots: “Write 1” time slots and “Write 0” time slots. The bus master uses a Write 1
time slot to write a logic 1 to the DS1825 and a Write 0 time slot to write a logic 0 to the DS1825. All write time slots
must be a minimum of 60ms in duration with a minimum of a
types of write time slots are initiated by the master pulling the 1-Wire bus low (see Figure 14).
To generate a Write 1 time slot, after pulling the 1-Wire bus low, the bus master must release the 1-Wire bus within
15ms. When the bus is released, the 5k pullup resistor will pull the bus high. To generate a Write 0 time slot, after
pulling the 1-Wire bus low, the bus master must continue to hold the bus low for the duration of the time slot (at
least 60ms).
The DS1825 samples the 1-Wire bus during a window that lasts from 15ms to 60ms after the master initiates the
write time slot. If the bus is high during the sampling window, a 1 is written to the DS1825. If the line is low, a 0 is
written to the DS1825.
Figure 14. INITIALIZATION TIMING
1-WIRE BUS
GND
V
PU
MASTER T
480 ms minimum
X
waits 15-60 ms
RESET PULSE
DS1825
LINE TYPE LEGEND
Bus master pulling low
DS1825 pulling low
Resistor pullup
16 of 21
1
X
m
) the reset pulse by pulling the 1-Wire bus low for a
s
presence pulse
recovery time between individual write slots. Both
DS1825 T
60-240 ms
480 ms minimum
MASTER R
X
X
X
). When the bus is