PS11017 Powerex Inc, PS11017 Datasheet - Page 4

no-image

PS11017

Manufacturer Part Number
PS11017
Description
IC CONV AC-DC 3-PHASE 600V 50A
Manufacturer
Powerex Inc
Datasheet

Specifications of PS11017

Voltage - Output
600V
Number Of Outputs
1
Power (watts)
30000W
Applications
Commercial
Power Supply Type
Switching (Closed Frame)
Voltage - Input
450VAC
Mounting Type
Through Hole
1st Output
600 VDC @ 50A
Size / Dimension
4.53" L x 2.99" W x 0.8" H (115mm x 76mm x 20.4mm)
Power (watts) - Rated
30000W
Operating Temperature
-20°C ~ 100°C
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
PS11017
Manufacturer:
MITSUBISHI
Quantity:
45
Part Number:
PS11017
Manufacturer:
MITSUBISHI
Quantity:
530
Part Number:
PS11017
Manufacturer:
MITSUBISHI/三菱
Quantity:
20 000
Part Number:
PS11017-A
Manufacturer:
MITSUBISHI
Quantity:
560
ELECTRICAL CHARACTERISTICS
(Note 3) : (a) Allowable minimum input on-pulse width : This item applies to P-side circuit only.
(Note4) : CL output : The "current limit warning (CL) operation circuit outputs warning signal whenever the arm current exceeds this limit. The
(Note5) : The short circuit protection works instantaneously when a high short circuit current flows through an internal IGBT rising up momen-
RECOMMENDED CONDITIONS
f
t
t
t
V
V
V
| V
V
V
r
t
I
I
SC
OT
OTr
UV
UV
OV
OV
UV
UV
t
I
I
V
V
V
V
f
t
PWM
xx
dead
int
d(read)
CL(H)
CL(L)
dV
FO(H)
FO(L)
PWM
dead
CH
Symbol
Symbol
V
V
I
CO
C+
C–
C+
C–
CC
DH
CIN(on)
CIN(off)
OL
DH
C
DH
DHr
DB
DBr
DH
DHr
CO
(200%)
(200%)
(200%)
, V
, V
|
DB
DB
(b) Allowable maximum input on-pulse width : This item applies to both P-side and N-side circuits excluding the brake circuit.
circuit is reset automatically by the next input signal and thus, it operates on a pulse-by-pulse scheme.
tarily. The protection function is, thus meant primarily to protect the ASIPM against short circuit distraction. Therefore, this function is
not recommended to be used for any system load current regulation or any over load control as this might, cause a failure due to
excessive temperature rise. Instead, the analogue current output feature or the over load warning feature (CL) should be appropri-
ately used for such current regulation or over load control operation. In other words, the PWM signals to the ASIPM should be shut
down, in principle, and not to be restarted before the junction temperature would recover to normal, as soon as a fault is feed back
from its F
PWM input frequency
Allowable input on-pulse width
Allowable input signal dead time for
blocking arm shoot-through
Input inter-lock sensing
Analogue signal linearity with output current
Offset change area vs temperature
Analogue signal output voltage limit
Analogue signal over all linear variation
Analogue signal data hold accuracy
Analogue signal reading time
Signal output current of
CL operation
CL warning operation level
Short circuit over current trip level
Fault output current
Supply voltage
Control Supply voltage
Supply voltage ripple
Input on voltage
Input off voltage
PWM Input frequency
Arm shoot-through blocking time
Over temperature
protection
Supply circuit under &
over voltage protection
O1
pin of the ASIPM indicating a short circuit situation.
Item
Item
Idle
Active
Trip level
Reset level
Trip level
Reset level
Trip level
Reset level
Trip level
Reset level
Filter time
Idle
Active
(Tj = 25 C, V
Applied between V
C
Using application circuit
Using application circuit
Applied across P-N terminals
BW+
-C
BW–
T
V
Relates to corresponding inputs,
(Except brake part), T
Relates to corresponding input (Except break part)
Ic = 0A
Ic = I
Ic = –I
V
Ic > I
|V
Correspond to max. 500 s data hold period
only, Ic = I
After input signal trigger point
Open collector output
V
V
T
Tj
Open collector output
Tj = 25 C
DH
C
DH
DH
D
DH
C
CO
= –20 ~ +100 C,
= 15V, T
= 15V, V
125 C
= 15V, T
= 15V, T
-V
= 15V
OP
OP
100 C, Tj
OP
C
(200%)
(200%), V
(200%)
DH
(200%)|
OP
C
-GND, C
DB
(200%)
C
C
= –20 C ~ 100 C
Condition
= –20 C ~ +100 C
= –20 C ~ 100 C
= 15V unless otherwise noted)
125 C
DH
Condition
BU+
= 15V
C
= –20 C ~ +100 C
V
T
-C
C
DH
BU–
= –20 C ~ 100 C
= 15V
(Fig. 7) (Note 5)
, C
BV+
-C
(Note 3)
(Note 4)
(Fig. 4)
(Fig. 4)
(Fig. 5)
(Fig. 8)
BV–
,
11.05
11.55
18.00
16.50
Min.
1.87
0.77
2.97
48.2
79.2
10.0
10.5
100
2.5
4.0
–5
1
400 (max.)
2.5 (min.)
4.8 ~ 5.0
Ratings
Ratings
1 (max.)
0 ~ 0.3
2 ~ 15
15 1.5
12.00
12.50
19.20
17.50
Typ.
2.27
1.17
3.37
60.0
11.0
11.5
102
110
1.1
65
15
90
10
3
1
1
INSULATED TYPE
FLAT-BASE TYPE
PS11017
12.75
13.25
20.15
18.65
12.5
Max.
2.57
1.47
3.67
72.0
12.0
500
100
120
0.7
15
5
1
1
May 2001
V/ s
Unit
Unit
kHz
kHz
mV
mA
mA
ns
%
V
V
V
V
V
V
V
A
A
V
V
V
V
V
V
V
V
V
C
C
s
s
s
A
s
A
s

Related parts for PS11017