JC050C1 Lineage Power, JC050C1 Datasheet - Page 2

no-image

JC050C1

Manufacturer Part Number
JC050C1
Description
CONVERTER DC/DC 15V 50W OUT
Manufacturer
Lineage Power
Series
JC050r
Type
Isolated with Remote On/Offr
Datasheet

Specifications of JC050C1

Output
15V
Number Of Outputs
1
Power (watts)
50W
Mounting Type
Through Hole
Voltage - Input
18 ~ 36V
Package / Case
9-DIP Module
1st Output
15 VDC @ 3.33A
Size / Dimension
2.40" L x 2.28" W x 0.50" H (61mm x 57.9mm x 12.7mm)
Power (watts) - Rated
50W
Operating Temperature
-40°C ~ 100°C
Efficiency
88%
Approvals
CSA, UL, VDE
Product
Isolated
Output Power
50 W
Input Voltage Range
18 V to 36 V
Input Voltage (nominal)
28 V
Output Voltage (channel 1)
15 V
Output Current (channel 1)
3.33 A
Isolation Voltage
1.5 KV
Package / Case Size
DIP
Output Type
Isolated
Output Voltage
15 V
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
3rd Output
-
2nd Output
-
4th Output
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
JC050C1
Manufacturer:
LUCENT
Quantity:
1 000
Part Number:
JC050C1
Quantity:
55
JC050C, JC075C, JC100C Power Modules: dc-dc Converters;
18 Vdc to 36 Vdc Input, 15 Vdc Output; 50 W to 100 W
Absolute Maximum Ratings
Stresses in excess of the absolute maximum ratings can cause permanent damage to the device. These are abso-
lute stress ratings only. Functional operation of the device is not implied at these or any other conditions in excess
of those given in the operations sections of the data sheet. Exposure to absolute maximum ratings for extended
periods can adversely affect device reliability.
Electrical Specifications
Unless otherwise indicated, specifications apply over all operating input voltage, resistive load, and temperature
conditions.
Table 1. Input Specifications
Fusing Considerations
CAUTION: This power module is not internally fused. An input line fuse must always be used.
This encapsulated power module can be used in a wide variety of applications, ranging from simple stand-alone
operation to an integrated part of a sophisticated power architecture. To preserve maximum flexibility, internal fus-
ing is not included; however, to achieve maximum safety and system protection, always use an input line fuse. The
safety agencies require a normal-blow, dc fuse with a maximum rating of 20 A (see Safety Considerations section).
Based on the information provided in this data sheet on inrush energy and maximum dc input current, the same
type of fuse with a lower rating can be used. Refer to the fuse manufacturer’s data for further information.
2
Operating Input Voltage
Maximum Input Current
Inrush Transient
Input Reflected-ripple Current, Peak-to-peak
Input Ripple Rejection (120 Hz)
Input Voltage Continuous
I/O Isolation Voltage
Operating Case Temperature
Storage Temperature
(V
(5 Hz to 20 MHz, 12 µH source impedance;
see Figure 11.)
(See Thermal Considerations section.)
JC050C (See Figure 1)
JC075C
JC100C (See Figure 2.)
I
= 0 V to 36 V; I
Parameter
O
Parameter
= I
O, max
):
Symbol
Symbol
T
T
V
stg
I
I
I
C
I, max
I, max
I, max
I
V
i
2
t
I
Min
18
Min
–40
–55
Typ
28
60
5
1500
Max
100
125
50
Max
3.5
5.2
6.9
1.0
36
Lineage Power
March 2008
Data Sheet
Unit
Vdc
Vdc
°C
°C
mAp-p
Unit
Vdc
A
dB
A
A
A
2
s

Related parts for JC050C1