JAHW100Y1 Lineage Power, JAHW100Y1 Datasheet - Page 10

no-image

JAHW100Y1

Manufacturer Part Number
JAHW100Y1
Description
CONVERTER DC/DC 1.8V 36W OUT
Manufacturer
Lineage Power
Series
JAHWr
Type
Isolated with Remote On/Offr
Datasheet

Specifications of JAHW100Y1

Output
1.8V
Number Of Outputs
1
Power (watts)
36W
Mounting Type
Through Hole
Voltage - Input
36 ~ 75V
Package / Case
9-DIP Module
1st Output
1.8 VDC @ 20A
Size / Dimension
2.40" L x 2.28" W x 0.50" H (61mm x 57.9mm x 12.7mm)
Power (watts) - Rated
36W
Operating Temperature
-40°C ~ 100°C
Efficiency
88.4%
Approvals
CE, CSA, UL, VDE
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
3rd Output
-
2nd Output
-
4th Output
-
dc-dc Converters; 36 to 75 Vdc Input, 1.8 Vdc Output; 18 W to 36 W
Feature Descriptions
Overcurrent Protection
To provide protection in an output overload condition,
the unit is provided with internal shutdown and auto-
restart mechanism.
At the instance of current-limit inception, the module
enters a "hiccup" mode of operation whereby it shuts
down and automatically attempts to restart. As long as
the fault persists, the module remains in this mode.
The protection mechanism is such that the unit can
continue in this condition for a sufficient interval of time
until the fault is cleared.
Remote On/Off
Two remote on/off options are available. Positive logic
remote on/off turns the module on during a logic-high
voltage on the ON/OFF pin, and off during a logic low.
Negative logic remote on/off turns the module off dur-
ing a logic high and on during a logic low. Negative
logic, device code suffix “1,” is the factory-preferred
configuration.
To turn the power module on and off, the user must
supply a switch to control the voltage between the
on/off terminal and the V
switch can be an open collector or equivalent (see
Figure 20). A logic low is V
maximum I
should maintain a logic-low voltage while sinking 1 mA.
During a logic high, the maximum V
the power module is 15 V. The maximum allowable
leakage current of the switch at V
If not using the remote on/off feature, do one of the
following to turn the unit on:
n
n
10
10
For negative logic, short ON/OFF pin to V
For positive logic, leave ON/OFF pin open.
on/off
during a logic low is 1 mA. The switch
I
(–) terminal (V
on/off
= 0 V to 1.2 V. The
on/off
on/off
= 15 V is 50 µA.
on/off
generated by
I
(–).
). The
Remote Sense
Remote sense minimizes the effects of distribution
losses by regulating the voltage at the remote-sense
connections. The voltage between the remote-sense
pins and the output terminals must not exceed the out-
put voltage sense range given in the Feature Specifica-
tions table, i.e.:
The voltage between the V
must not exceed the minimum output overvoltage shut-
down value indicated in the Feature Specifications
table. This limit includes any increase in voltage due to
remote-sense compensation and output voltage set-
point adjustment (trim). See Figure 21.
If not using the remote-sense feature to regulate the
output at the point of load, then connect SENSE(+) to
V
Although the output voltage can be increased by both
the remote sense and by the trim, the maximum
increase for the output voltage is not the sum of both.
The maximum increase is the larger of either the
remote sense or the trim. Consult the factory if you
need to increase the output voltage more than the
above limitation.
The amount of power delivered by the module is defined
as the voltage at the output terminals multiplied by the
output current. When using remote sense and trim, the
output voltage of the module can be increased, which at
the same output current would increase the power output
of the module. Care should be taken to ensure that the
maximum output power of the module remains at or
below the maximum rated power.
O
[V
(+) and SENSE(–) to V
Figure 20. Remote On/Off Implementation
O
(+) – V
V
I
on/off
on/off
+
O
(–)] – [SENSE(+) – SENSE(–)] ≤ 0.5 V
ON/OFF
V
V
I
I
(+)
(–)
O
O
(–) at the module.
(+) and V
SENSE(+)
SENSE(–)
V
V
O
O
(+)
(–)
O
(–) terminals
Lineage Power
April 2008
8-720 (F).c
LOAD