JAHW100Y1 Lineage Power, JAHW100Y1 Datasheet - Page 9

no-image

JAHW100Y1

Manufacturer Part Number
JAHW100Y1
Description
CONVERTER DC/DC 1.8V 36W OUT
Manufacturer
Lineage Power
Series
JAHWr
Type
Isolated with Remote On/Offr
Datasheet

Specifications of JAHW100Y1

Output
1.8V
Number Of Outputs
1
Power (watts)
36W
Mounting Type
Through Hole
Voltage - Input
36 ~ 75V
Package / Case
9-DIP Module
1st Output
1.8 VDC @ 20A
Size / Dimension
2.40" L x 2.28" W x 0.50" H (61mm x 57.9mm x 12.7mm)
Power (watts) - Rated
36W
Operating Temperature
-40°C ~ 100°C
Efficiency
88.4%
Approvals
CE, CSA, UL, VDE
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
3rd Output
-
2nd Output
-
4th Output
-
April 2008
Test Configurations
Note: Measure input reflected-ripple current with a simulated source
Note: Use a 1.0 µF ceramic capacitor and a 10 µF aluminum or tan-
Figure 18. Peak-to-Peak Output Noise
Note: All measurements are taken at the module terminals. When
Figure 19. Output Voltage and Efficiency
Lineage Power
BATTERY
Figure 17. Input Reflected-Ripple Test Setup
SUPPLY
η
inductance (L
tery impedance. Measure current as shown above.
talum capacitor. Scope measurement should be made using a
BNC socket. Position the load between 51 mm and 76 mm
(2 in. and 3 in.) from the module.
socketing, place Kelvin connections at module terminals to
avoid measurement errors due to socket contact resistance.
RESISTANCE
V
V
=
CONTACT
O
O
(+)
(–)
TO OSCILLOSCOPE
[
----------------------------------------------- -
V
[
Measurement Test Setup
Measurement Test Setup
I
V
I
O
I
(+) – V
(+) – V
TEST
COPPER STRIP
1.0 μF
C
ESR < 0.1 Ω
@ 20 °C, 100 kHz
) of 12 µH. Capacitor C
V
V
S
I
I
(+)
(–)
220 μF
O
I
(–)
(–)
12 μH
L
SENSE(+)
SENSE(–)
TEST
]I
]I
10 μF
I
O
dc-dc Converters; 36 to 75 Vdc Input, 1.8 Vdc Output; 18 W to 36 W
V
V
⎞ x 100
O
O
(+)
(–)
ESR < 0.7 Ω
SCOPE
@ 100 kHz
DISTRIBUTION LOSSES
CURRENT
S
I
33 μF
O
PROBE
%
offsets possible bat-
CONTACT AND
RESISTIVE
LOAD
LOAD
8-513 (F).d
8-203 (F).l
8-749 (F)
V
V
I
I
(+)
(–)
Design Considerations
Input Source Impedance
The power module should be connected to a low
ac-impedance input source. Highly inductive source
impedances can affect the stability of the power mod-
ule. For the test configuration in Figure 17, a 33 µF
electrolytic capacitor (ESR < 0.7 Ω at 100 kHz)
mounted close to the power module helps ensure sta-
bility of the unit. For other highly inductive source
impedances, consult the factory for further application
guidelines.
Safety Considerations
For safety-agency approval of the system in which the
power module is used, the power module must be
installed in compliance with the spacing and separation
requirements of the end-use safety agency standard,
i.e., UL60950, CSA C22.2 No. 60950-00, and VDE
0805 (IEC60950).
If the input source is non-SELV (ELV or a hazardous
voltage greater than 60 Vdc and less than or equal to
75 Vdc), for the module’s output to be considered
meeting the requirements of safety extra-low voltage
(SELV), all of the following must be true:
n
n
n
n
Note: Do not ground either of the input pins of the
The power module has extra-low voltage (ELV) outputs
when all inputs are ELV.
The input to these units is to be provided with a maxi-
mum 6 A normal-blow fuse in the ungrounded lead.
The input source is to be provided with reinforced
insulation from any hazardous voltages, including the
ac mains.
One V
both the input and output pins are to be kept floating.
The input pins of the module are not operator acces-
sible.
Another SELV reliability test is conducted on the
whole system, as required by the safety agencies, on
the combination of supply source and the subject
module to verify that under a single fault, hazardous
voltages do not appear at the module’s output.
module without grounding one of the output pins.
This may allow a non-SELV voltage to appear
between the output pin and ground.
I
pin and one V
O
pin are to be grounded, or
9

Related parts for JAHW100Y1