JAHW100Y1 Lineage Power, JAHW100Y1 Datasheet - Page 13

no-image

JAHW100Y1

Manufacturer Part Number
JAHW100Y1
Description
CONVERTER DC/DC 1.8V 36W OUT
Manufacturer
Lineage Power
Series
JAHWr
Type
Isolated with Remote On/Offr
Datasheet

Specifications of JAHW100Y1

Output
1.8V
Number Of Outputs
1
Power (watts)
36W
Mounting Type
Through Hole
Voltage - Input
36 ~ 75V
Package / Case
9-DIP Module
1st Output
1.8 VDC @ 20A
Size / Dimension
2.40" L x 2.28" W x 0.50" H (61mm x 57.9mm x 12.7mm)
Power (watts) - Rated
36W
Operating Temperature
-40°C ~ 100°C
Efficiency
88.4%
Approvals
CE, CSA, UL, VDE
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
3rd Output
-
2nd Output
-
4th Output
-
April 2008
Thermal Considerations
Introduction
The temperature at this location should not exceed
100 °C. The output power of the module should not
exceed the rated power for the module as listed in the
Ordering Information table.
Although the maximum case temperature of the power
modules is 100 °C, you can limit this temperature to a
lower value for extremely high reliability.
Heat Transfer Without Heat Sinks
Increasing airflow over the module enhances the heat
transfer via convection. Figure 26 shows the maximum
power that can be dissipated by the module without
exceeding the maximum case temperature versus local
ambient temperature (T
through 3 m/s (600 ft./min.).
Note that the natural convection condition was mea-
sured at 0.05 m/s to 0.1 m/s (10 ft./min. to 20 ft./min.);
however, systems in which these power modules may
be used typically generate natural convection airflow
rates of 0.3 m/s (60 ft./min.) due to other heat dissipat-
ing components in the system. The use of Figure 26 is
shown in the following example.
Example
What is the minimum airflow necessary for a
JAHW100Y operating at V
20 A, and a maximum ambient temperature of 65 °C?
Solution
Given: V
Determine P
Determine airflow (v) (Use Figure 26.):
Lineage Power
I
T
P
v = 0.46 m/s (90 ft./min.)
O
A
I
D
= 20 A
= 48 V
= 65 °C
= 5.2 W
D
(Use Figure 29.):
(continued)
A
) for natural convection
I
= 48 V, an output current of
dc-dc Converters; 36 to 75 Vdc Input, 1.8 Vdc Output; 18 W to 36 W
(continued)
Figure 26. Forced Convection Power Derating with
Figure 27. JAHW050Y Power Dissipation vs.
4.5
3.5
2.5
1.5
0.5
7
6
5
4
3
2
1
0
4
3
2
1
0
0
0
3.0 m/s (600 ft./min.)
2.0 m/s (400 ft./min.)
1.0 m/s (200 ft./min.)
0.1 m/s (20 ft./min.)
(NATURAL CONVECTION)
No Heat Sink; Either Orientation
Output Current at 25 °C
10
1
LOCAL AMBIENT TEMPERATURE, T
LOCAL AMBIENT TEMPERATURE, T
20
2
30
3
40
4
50
5
60
6
70
7
V
V
V
I
I
I
= 75 V
= 48 V
= 36 V
80
8
A
A
(°C)
(°C)
90 100
9 10
8-3246 (F)
8-3247 (F)
13