ZUP20-10/U TDK Corporation, ZUP20-10/U Datasheet - Page 20

PWR SUP BENCH PROG 0-20V 200W

ZUP20-10/U

Manufacturer Part Number
ZUP20-10/U
Description
PWR SUP BENCH PROG 0-20V 200W
Manufacturer
TDK Corporation
Series
ZUPr
Type
Programmabler
Datasheets

Specifications of ZUP20-10/U

Load Regulation
0.01%
Voltage - Output
0 ~ 20V
Number Of Outputs
1
Power (watts)
200W
Applications
Commercial
Power Supply Type
Switching (Closed Frame)
Voltage - Input
85 ~ 265VAC
Mounting Type
Chassis Mount
1st Output
0 ~ 20 VDC @ 10A
Size / Dimension
13.78" L x 4.88" W x 2.76" H (350mm x 124mm x 70mm)
Power (watts) - Rated
200W
Operating Temperature
0°C ~ 50°C
Efficiency
78%
Approvals
CE, EN, UL
Line Regulation
0.01%
Power Supply Output Type
Variable
No. Of Outputs
1
Output Voltage
20V
Output Current
10A
Power Rating
200W
Input Voltage
85V AC To 265V AC
Length
350mm
Width
70mm
Accuracy
0.02% + 12 mV
Brand/series
ZUP
Current, Output
10 A
Display Type
Digital Meter
Power, Output
200 W
Power, Rating
200 W (Max.)
Regulation, Line
0.01% + 2 mA⁄1 mV + 0.005%
Regulation, Load
0.01% + 5 mA⁄2 mV + 0.005%
Standards
UL Listed, CE Marked
Temperature Coefficient
30 ppm⁄°C (CV)⁄100 ppm⁄°C (CC)
Temperature, Operating, Maximum
50 °C
Temperature, Operating, Minimum
0 °C
Voltage, Input
85-265 VAC
Voltage, Noise
50 mV @ 20 MHz BW
Voltage, Output
20 VDC
Voltage, Ripple
5 mV @ 5 Hz to 1 MHz
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
3rd Output
-
2nd Output
-
4th Output
-
Lead Free Status / Rohs Status
RoHS Compliant part
Other names
285-1673
Q1142280
ZUP20-10/U
ZUP2010/U
For current not shown in tables 3-1 and 3-2 use formula: Maximum length=500/(current*resistivity)
Where current is expressed in ampers and resistivity in ohms/km or ohms/1000ft.
3.7.2 Wire termination
3.7.3 Single load connection, Local Sensing
COM
VCVP
VCCP
RCCP
Fig. 3-1: Single load connection, Local Sensing
The wires should be properly terminated with terminals securely attached. DO NOT use non
terminated wires for load connection at the power supply.
Fig. 3-1 illustrates the connection of a single load to the power supply using local sensing. This
connection is made via the “External Control Connector” located on the rear panel of the power supply.
Local sensing is suitable for applications where load regulation is not critical.
- S
+S
P
EXTERNAL CONTROL
(ZUP rear panel view)
14
2
At local sensing, short between +LS or +S to -V or -S or -LS will cause damage to the
CONNECTOR
power supply. Reversing the sense wires might cause damage to the power supply
13
1
On/Off
Output Good
VRFV
VRFI
RCVP
Table 3-2: Maximum wire length for 0.5V drop on lead (in meters)
- LS
+LS
2.5
10
16
25
35
4
6
<
0.795
0.565
8.21
5.09
3.39
1.95
1.24
at local and remote sensing.
125.8
177.0
12.2
19.6
29.5
51.3
80.6
5A
Maximum length in meters -
to limit voltage drop to 0.5V or less
CAUTION
SUPPLY
POWER
14.7
25.6
40.3
62.9
88.5
10A
6.1
9.8
12.8
20.2
31.4
44.2
20A
3.0
4.9
7.4
- LS
+LS
- V
- S
+ S
- S
+V
12.6
17.7
50A
5.1
1.2
2.0
2.9
8.1
150A
0.4
0.7
1.0
1.7
2.7
4.2
5.9
+
_
LOAD

Related parts for ZUP20-10/U