ZUP20-10/U TDK Corporation, ZUP20-10/U Datasheet - Page 22

PWR SUP BENCH PROG 0-20V 200W

ZUP20-10/U

Manufacturer Part Number
ZUP20-10/U
Description
PWR SUP BENCH PROG 0-20V 200W
Manufacturer
TDK Corporation
Series
ZUPr
Type
Programmabler
Datasheets

Specifications of ZUP20-10/U

Load Regulation
0.01%
Voltage - Output
0 ~ 20V
Number Of Outputs
1
Power (watts)
200W
Applications
Commercial
Power Supply Type
Switching (Closed Frame)
Voltage - Input
85 ~ 265VAC
Mounting Type
Chassis Mount
1st Output
0 ~ 20 VDC @ 10A
Size / Dimension
13.78" L x 4.88" W x 2.76" H (350mm x 124mm x 70mm)
Power (watts) - Rated
200W
Operating Temperature
0°C ~ 50°C
Efficiency
78%
Approvals
CE, EN, UL
Line Regulation
0.01%
Power Supply Output Type
Variable
No. Of Outputs
1
Output Voltage
20V
Output Current
10A
Power Rating
200W
Input Voltage
85V AC To 265V AC
Length
350mm
Width
70mm
Accuracy
0.02% + 12 mV
Brand/series
ZUP
Current, Output
10 A
Display Type
Digital Meter
Power, Output
200 W
Power, Rating
200 W (Max.)
Regulation, Line
0.01% + 2 mA⁄1 mV + 0.005%
Regulation, Load
0.01% + 5 mA⁄2 mV + 0.005%
Standards
UL Listed, CE Marked
Temperature Coefficient
30 ppm⁄°C (CV)⁄100 ppm⁄°C (CC)
Temperature, Operating, Maximum
50 °C
Temperature, Operating, Minimum
0 °C
Voltage, Input
85-265 VAC
Voltage, Noise
50 mV @ 20 MHz BW
Voltage, Output
20 VDC
Voltage, Ripple
5 mV @ 5 Hz to 1 MHz
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
3rd Output
-
2nd Output
-
4th Output
-
Lead Free Status / Rohs Status
RoHS Compliant part
Other names
285-1673
Q1142280
ZUP20-10/U
ZUP2010/U
External Control Connector pin
3.7.6 Multiple load connections with distribution terminals
If remotely located output distribution terminals are used, the power supply output terminals should be
connected to the distribution terminals by a pair of twisted or shielded wires. Each load should be
separately connected to the remote distribution terminals. If Remote Sensing is required, the sensing
wires should be connected to the distribution terminals or at the most critical load.
3.7.7 Grounding outputs
Either the positive or negative output terminals can be grounded. To avoid noise problems caused by
common-mode current flowing from the load to ground, it is recommended to ground the output
terminal as close as possible to the power supply output.
Always use two wires to connect the load to the power supply regardless of how the system is
grounded.
The maximum potential (including output voltage) that either output terminal
is from ground, must not exceed the specified voltage on the front panel.
3.8 EXTERNAL CONTROL CONNECTOR
3.8.1 General
Fig. 3-5:
COM
VCVP
VCCP
RCCP
The external control connector, used for analog programming of the power supply, is located on the
rear panel of the unit,(Fig. 4-2, item 4). The pin assignment is shown in Fig. 3-5 below.
assignment (ZUP rear panel view)
Fig. 3-4: Multiple load connections with distribution terminal
- S
+S
P
EXTERNAL CONTROL
(ZUP rear panel view)
CONNECTOR
2
1
On/Off
Output Good
VRFV
VRFI
RCVP
- LS
+LS
14
2
To Dristribution Terminals
13
POWER
SUPPLY
1
The External Control Connector signals are connected to the
negative output terminal. If the negative output terminal is
floated with respect to chassis ground , those signals will also
float at the same potential. Use appropriate safety measures
to prevent a shock hazard.
WARNING
- S
+S
+V
- V
WARNING
DISTRIBUTION
TERMINAL
- V
+V
+
+
+
_
_
_
LOAD #1
LOAD #2
LOAD #3