H5CX-L8-N AC100-240 Omron, H5CX-L8-N AC100-240 Datasheet - Page 31

RELAY TIMER DGTL SPDT 100/240VAC

H5CX-L8-N AC100-240

Manufacturer Part Number
H5CX-L8-N AC100-240
Description
RELAY TIMER DGTL SPDT 100/240VAC
Manufacturer
Omron
Series
H5CXr
Datasheets

Specifications of H5CX-L8-N AC100-240

Relay Type
Integrated
Function
Programmable (Multi-Function)
Circuit
SPDT (1 Form C)
Delay Time
0.001 Sec ~ 9999 Hrs
Output Type
Mechanical Relay
Contact Rating @ Voltage
5A @ 250VAC
Voltage - Supply
100 ~ 240VAC
Mounting Type
Socket
Termination Style
8 Pin Socketable
Timing Adjustment Method
Up/Down Digit Keys
Timing Initiate Method
Input Voltage, Trigger Signal
Time Range
0.001s-9999hr
Power Consumption
6.2VA
Reset Time
20ms
Character Size
11.5mm
Time Range Min
0.001s
Supply Voltage Min
100VAC
Connector Type
8-Pin Socket
Signal Input Type
PNP/NPN
No. Of Digits / Alpha
4
Rohs Compliant
Yes
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
For Use With
PNP/NPN
Lead Free Status / RoHS Status
Lead free / RoHS Compliant, Lead free / RoHS Compliant
Other names
H5CXL8NAC100240
Z2999
■ Operation in Timer/Twin Timer Selection Mode
Select whether the H5CX is used as a timer or a twin timer in timer/twin timer selection mode. The H5CX is also equipped with a DIP switch monitor
function, a convenient function that enables the settings of the DIP switch pins to be confirmed using the front display.
Note 1. When the mode is changed to timer/twin timer selection mode, the present value is reset and output turns OFF. Timing operation is not
2. Setting changes made in timer/twin timer selection mode are enabled when the mode is changed to run mode. If settings are changed, the
performed in timer/twin timer selection mode.
HC5X is automatically reset (present value initialized, output turned OFF).
Power ON
1 s min.
+
1
Timer/Twin
timer selection
DIP switch
monitor
To change the mode to timer/twin timer selection mode, hold
down the
The
If the
Select either timer operation or twin timer operation
using the
Note: The H5CX is factory-set for timer operation.
Confirm the status of DIP switch pins 1 to 8 using
the
Note 1. This display is not supported with H5CX-L8@.
OFF
ON
(Timer)
MODE
2. This display is only possible when DIP switch pin 1
Example
(DIP switch settings enable/disable) is set to ON
(enable).
1
key must be pressed before the
key is pressed first, the mode will not change.
keys.
1
1
(Twin timer)
key for 1 s min. with the
2
keys.
3
4
5
6
7
8
MODE
1
key held down.
key.
Indicates that DIP switch pin 8 is ON.
Indicates that DIP switch pin 7 is OFF.
Indicates that DIP switch pin 6 is ON.
Indicates that DIP switch pin 5 is OFF.
Indicates that DIP switch pin 4 is ON.
Indicates that DIP switch pin 3 is OFF.
Indicates that DIP switch pin 2 is ON.
Indicates that DIP switch pin 1 is ON.