H5CX-L8-N AC100-240 Omron, H5CX-L8-N AC100-240 Datasheet - Page 46

RELAY TIMER DGTL SPDT 100/240VAC

H5CX-L8-N AC100-240

Manufacturer Part Number
H5CX-L8-N AC100-240
Description
RELAY TIMER DGTL SPDT 100/240VAC
Manufacturer
Omron
Series
H5CXr
Datasheets

Specifications of H5CX-L8-N AC100-240

Relay Type
Integrated
Function
Programmable (Multi-Function)
Circuit
SPDT (1 Form C)
Delay Time
0.001 Sec ~ 9999 Hrs
Output Type
Mechanical Relay
Contact Rating @ Voltage
5A @ 250VAC
Voltage - Supply
100 ~ 240VAC
Mounting Type
Socket
Termination Style
8 Pin Socketable
Timing Adjustment Method
Up/Down Digit Keys
Timing Initiate Method
Input Voltage, Trigger Signal
Time Range
0.001s-9999hr
Power Consumption
6.2VA
Reset Time
20ms
Character Size
11.5mm
Time Range Min
0.001s
Supply Voltage Min
100VAC
Connector Type
8-Pin Socket
Signal Input Type
PNP/NPN
No. Of Digits / Alpha
4
Rohs Compliant
Yes
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
For Use With
PNP/NPN
Lead Free Status / RoHS Status
Lead free / RoHS Compliant, Lead free / RoHS Compliant
Other names
H5CXL8NAC100240
Z2999
■ Timing Charts
Note: Forecast Value = Set Value − Forecast Set Value
■ Self-diagnostic Function
The following displays will appear if an error occurs.
Note: This includes times when the life of the EEPROM has expired.
e1
e2
e2
Forecast value (SV 1)
Forecast value (SV 1)
Main display
Set value (SV 2)
Set value (SV 2)
The forecast set value is used to set the deviation for the set value.
Start signal
Start signal
Power
999999
Reset
Gate
OUT1
OUT2
999999
Power
Reset
OUT1
OUT2
Gate
0
0
The names in parentheses are used for the absolute value setting.
The names in parentheses are used for the absolute value setting.
Not lit
Not lit
sum
Sub-display
F-1 mode: Cumulative (Timer does not reset when power comes ON.)
A Mode: Signal ON delay (Timer resets when power comes ON.)
CPU
Memory error (RAM)
Memory error (EEP)
(See note)
Error
OFF
OFF
OFF
Output status
Either press the reset key or reset the
power supply.
Reset the power supply.
Reset to the factory settings using
the reset key.
(Control output 2)
Start signal input
(Control output 2)
(Control output 1)
Basic Operation
*
**
(Control output 1)
Start signal input
Basic Operation
*
Forecast output
Forecast output
Correction method
Timing starts when the start signal turns ON.
While the start signal is ON, the timer starts when the power
turns ON or when the reset input turns OFF.
A sustained control output is used.
Timing stops when the time is up.
Control output
Control output
Output is instantaneous when the set value is 0.
Output is instantaneous when the set value is 0.
Start signal input is disabled during timing.
Start signal enables timing (timing is stopped when the
start signal is OFF or when the power is OFF).
A sustained control output is used.
Timing continues even after the time is up.
Power
OUT2
OUT2
OUT1
Power
OUT1
**
The names in parentheses are used for the
absolute value setting.
The names in parentheses are used for
the absolute value setting.
Timing
Sustained
Timing
No change
No change
0
Set value after
H5CX-B
Timing
reset
46