ZLP32300H2832G Zilog, ZLP32300H2832G Datasheet - Page 32

IC CRIMZON Z8 MCU OTP 32K 28SSOP

ZLP32300H2832G

Manufacturer Part Number
ZLP32300H2832G
Description
IC CRIMZON Z8 MCU OTP 32K 28SSOP
Manufacturer
Zilog
Series
Crimzon™ ZLPr
Datasheets

Specifications of ZLP32300H2832G

Core Processor
Z8
Core Size
8-Bit
Speed
8MHz
Peripherals
Brown-out Detect/Reset, HLVD, POR, WDT
Number Of I /o
24
Program Memory Size
32KB (32K x 8)
Program Memory Type
OTP
Ram Size
237 x 8
Voltage - Supply (vcc/vdd)
2 V ~ 3.6 V
Oscillator Type
Internal
Operating Temperature
0°C ~ 70°C
Package / Case
28-SSOP
Data Bus Width
8 bit
Data Ram Size
237 B
Maximum Clock Frequency
8 MHz
Number Of Programmable I/os
24
Number Of Timers
2
Operating Supply Voltage
2 V to 3.6 V
Maximum Operating Temperature
+ 70 C
Mounting Style
SMD/SMT
Minimum Operating Temperature
0 C
For Use With
269-4665 - KIT REMOTE UNVRSL USA 6-FUNCTION
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Eeprom Size
-
Data Converters
-
Connectivity
-
Lead Free Status / Rohs Status
 Details
Other names
269-4507
ZLP32300H2832G
PS020823-0208
Caution:
Note:
T8 Enable
This field enables T8 when set (written) to 1.
Single/Modulo-N
When set to 0 (Modulo-N), the counter reloads the initial value when the terminal count is
reached. When set to 1 (single-pass), the counter stops when the terminal count is reached.
Timeout
This bit is set when T8 times out (terminal count reached). To reset this bit, write a 1 to its
location.
Ensure to manipulate CTR0, bit 5 and CTR1, bits 0 and 1 (DEMODULATION mode)
when using the OR or AND commands. These instructions use a Read-Modify-Write
sequence in which the current status from the CTR0 and CTR1 registers is ORed or
ANDed with the designated value and then written back into the registers.
T8 Clock
These bits define the frequency of the input signal to T8.
Capture_INT_Mask
Set this bit to allow an interrupt when data is captured into either LO8 or HI8 upon a posi-
tive or negative edge detection in DEMODULATION mode.
Counter_INT_Mask
Set this bit to allow an interrupt when T8 has a timeout.
P34_Out
This bit defines whether P34 is used as a normal output pin or the T8 output.
T8 and T16 Common Functions—CTR1(0D)01h
This register controls the functions in common with the T8 and T16.
Table 8
Writing a 1 is the only way to reset the Terminal Count status condition. Reset this bit
before using/enabling the counter/timers. The first clock of T8 might not have complete
clock width and can occur any time when enabled.
lists and briefly describes the fields for this register.