ZLP32300H2832G Zilog, ZLP32300H2832G Datasheet - Page 46

IC CRIMZON Z8 MCU OTP 32K 28SSOP

ZLP32300H2832G

Manufacturer Part Number
ZLP32300H2832G
Description
IC CRIMZON Z8 MCU OTP 32K 28SSOP
Manufacturer
Zilog
Series
Crimzon™ ZLPr
Datasheets

Specifications of ZLP32300H2832G

Core Processor
Z8
Core Size
8-Bit
Speed
8MHz
Peripherals
Brown-out Detect/Reset, HLVD, POR, WDT
Number Of I /o
24
Program Memory Size
32KB (32K x 8)
Program Memory Type
OTP
Ram Size
237 x 8
Voltage - Supply (vcc/vdd)
2 V ~ 3.6 V
Oscillator Type
Internal
Operating Temperature
0°C ~ 70°C
Package / Case
28-SSOP
Data Bus Width
8 bit
Data Ram Size
237 B
Maximum Clock Frequency
8 MHz
Number Of Programmable I/os
24
Number Of Timers
2
Operating Supply Voltage
2 V to 3.6 V
Maximum Operating Temperature
+ 70 C
Mounting Style
SMD/SMT
Minimum Operating Temperature
0 C
For Use With
269-4665 - KIT REMOTE UNVRSL USA 6-FUNCTION
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Eeprom Size
-
Data Converters
-
Connectivity
-
Lead Free Status / Rohs Status
 Details
Other names
269-4507
ZLP32300H2832G
PS020823-0208
Note:
This T16 mode is generally used to measure space time, the length of time between bursts
of carrier signal (marks).
If D6 of CTR2 Is 1
T16 ignores the subsequent edges in the input signal and continues counting down. A tim-
eout of T8 causes T16 to capture its current value and generate an interrupt if enabled
(CTR2, D2). In this case, T16 does not reload and continues counting. If the D6 bit of
CTR2 is toggled (by writing a 0 then a 1 to it), T16 captures and reloads on the next edge
(rising, falling, or both depending on CTR1, D5; D4), continuing to ignore subsequent
edges.
This T16 mode generally measures mark time, the length of an active carrier signal burst.
If T16 reaches 0, T16 continues counting from
is set, and an interrupt timeout can be generated if enabled (CTR2 D1).
PING-PONG Mode
This operation mode is only valid in TRANSMIT mode. T8 and T16 must be programmed
in SINGLE-PASS mode (CTR0, D6; CTR2, D6), and PING-PONG mode must be pro-
grammed in CTR1, D3; D2. You can begin the operation by enabling either T8 or T16
(CTR0, D7 or CTR2, D7). For example, if T8 is enabled, T8_OUT is set to this initial
value (CTR1, D1). According to T8_OUT's level, TC8H or TC8L is loaded into T8. After
the terminal count is reached, T8 is disabled, and T16 is enabled. T16_OUT then switches
to its initial value (CTR1, D0), data from TC16H and TC16L is loaded, and T16 starts to
count. After T16 reaches the terminal count, it stops, T8 is enabled again, repeating the
entire cycle. Interrupts can be allowed when T8 or T16 reaches terminal control (CTR0,
D1; CTR2, D1). To stop the Ping-Pong operation, write 00 to bits D3 and D2 of CTR1, see
Figure
Enabling Ping-Pong operation while the counter/timers are running might cause intermit-
tent counter/timer function. Disable the counter/timers and reset the status Flags before
instituting this operation.
Enable
Enable
26.
TC8
TC16
Figure 26. PING-PONG Mode Diagram
Timeout
Timeout
FFFFh
. Meanwhile, a status bit (CTR2 D5)
Ping-Pong
CTR1
Product Specification
Crimzon
Functional Description
®
ZLP32300
42