M30262F6GP#U3 Renesas Electronics America, M30262F6GP#U3 Datasheet - Page 36

IC M16C/TINY MCU FLASH 48LQFP

M30262F6GP#U3

Manufacturer Part Number
M30262F6GP#U3
Description
IC M16C/TINY MCU FLASH 48LQFP
Manufacturer
Renesas Electronics America
Series
M16C™ M16C/Tiny/26r
Datasheets

Specifications of M30262F6GP#U3

Core Processor
M16C/60
Core Size
16-Bit
Speed
20MHz
Connectivity
I²C, IEBus, SIO, UART/USART
Peripherals
DMA, WDT
Number Of I /o
38
Program Memory Size
48KB (48K x 8)
Program Memory Type
FLASH
Ram Size
2K x 8
Voltage - Supply (vcc/vdd)
2.7 V ~ 5.5 V
Data Converters
A/D 8x10b
Oscillator Type
Internal
Operating Temperature
-40°C ~ 85°C
Package / Case
48-LQFP
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Eeprom Size
-

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Company:
Part Number:
M30262F6GP#U3M30262F6GP#D3
Manufacturer:
Renesas Electronics America
Quantity:
10 000
Company:
Part Number:
M30262F6GP#U3M30262F6GP#D5
Manufacturer:
Renesas Electronics America
Quantity:
10 000
Company:
Part Number:
M30262F6GP#U3
Manufacturer:
Renesas Electronics America
Quantity:
10 000
Company:
Part Number:
M30262F6GP#U3M30262F6GP#U5
Manufacturer:
Renesas Electronics America
Quantity:
10 000
Company:
Part Number:
M30262F6GP#U3M30262F6GP#U9
Manufacturer:
Renesas Electronics America
Quantity:
10 000
1.9 Instruction Format
Chapter 1 Overview
The instruction format can be classified into four types: generic, quick, short, and zero. The number of
instruction bytes that can be chosen by a given format is least for the zero format, and increases succes-
sively for the short, quick, and generic formats in that order.
The following describes the features of each format.
1.9.1 Generic format (:G)
1.9.2 Quick format (:Q)
1.9.3 Short format (:S)
1.9.4 Zero format (:Z)
Op-code in this format consists of two bytes. This op-code contains information on operation and src
and dest
Instruction code here is comprised of op-code (2 bytes), src code (0-3 bytes), and dest code (0-3 bytes).
Op-code in this format consists of two bytes. This op-code contains information on operation and imme-
diate data and dest addressing modes. Note however that the immediate data in this op-code is a
numeric value that can be expressed by -7 to +8 or -8 to +7 (varying with instruction).
Instruction code here is comprised of op-code (2 bytes) containing immediate data and dest code (0-2
bytes).
Op-code in this format consists of one byte. This op-code contains information on operation and src and
dest addressing modes.Note however that the usable addressing modes are limited.
Instruction code here is comprised of op-code (1 byte), src code (0-2 bytes), and dest code (0-2 bytes).
Op-code in this format consists of one byte. This op-code contains information on operation (plus
immediate data) and dest addressing modes. Note however that the immediate data is fixed to 0, and
that the usable addressing modes are limited.
Instruction code here is comprised of op-code (1 byte) and dest code (0-2 bytes).
*1 src is the abbreviation of “source.”
*2 dest is the abbreviation of “destination.”
*2
addressing modes.
18
1.9 Instruction Format
*1