XC56309VF100A Freescale Semiconductor, XC56309VF100A Datasheet - Page 39

no-image

XC56309VF100A

Manufacturer Part Number
XC56309VF100A
Description
IC DSP 24BIT FIXED-POINT 196-BGA
Manufacturer
Freescale Semiconductor
Series
DSP563xxr
Type
Fixed Pointr
Datasheet

Specifications of XC56309VF100A

Interface
Host Interface, SSI, SCI
Clock Rate
100MHz
Non-volatile Memory
ROM (576 B)
On-chip Ram
24kB
Voltage - I/o
3.30V
Voltage - Core
3.30V
Operating Temperature
-40°C ~ 100°C
Mounting Type
Surface Mount
Package / Case
196-MAPBGA
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
XC56309VF100A
Manufacturer:
MOTOLOLA
Quantity:
437
Part Number:
XC56309VF100A
Manufacturer:
Freescale Semiconductor
Quantity:
10 000
Part Number:
XC56309VF100A
Manufacturer:
XILINX
0
Part Number:
XC56309VF100A
Manufacturer:
FREESCALE
Quantity:
20 000
Part Number:
XC56309VF100AR2
Manufacturer:
Freescale Semiconductor
Quantity:
10 000
Freescale Semiconductor
SCK0
PC3
SRD0
PC4
STD0
PC5
Notes: 1.
Signal
Name
2.
Input/Output
Input or Output
Input
Input or Output
Output
Input or Output
Table 2-12. Enhanced Synchronous Serial Interface 0 (ESSI0) (Continued)
In the Stop state, the signal maintains the last state as follows:
The Wait processing state does not affect the signal state.
Type
If the last state is input, the signal is an ignored input.
If the last state is output, these lines are tri-stated.
Ignored input
Ignored input
Ignored input
State During
Reset
1, 2
DSP56309 User’s Manual, Rev. 1
Serial Clock
Provides the serial bit rate clock for the ESSI interface for both the transmitter
and receiver in Synchronous modes, or the transmitter only in Asynchronous
modes.
Although an external serial clock can be independent of and asynchronous to
the DSP system clock, it must exceed the minimum clock cycle time of 6 T
(that is, the system clock frequency must be at least three times the external
ESSI clock frequency). The ESSI needs at least three DSP phases inside
each half of the serial clock.
Port C 3
The default configuration following reset is GPIO. For PC3, signal direction is
controlled through PRRC. This signal is configured as SCK0 or PC3 through
PCRC. This input is 5 V tolerant.
Serial Receive Data
Receives serial data and transfers the data to the ESSI receive shift register.
SRD0 is an input when data is being received.
Port C 4
The default configuration following reset is GPIO. For PC4, signal direction is
controlled through PRRC. This signal is configured as SRD0 or PC4 through
PCRC. This input is 5 V tolerant.
Serial Transmit Data
Transmits data from the serial transmit shift register. STD0 is an output when
data is being transmitted.
Port C 5
The default configuration following reset is GPIO. For PC5, signal direction is
controlled through PRRC. This signal is configured as STD0 or PC5 through
PCRC. This input is 5 V tolerant.
Enhanced Synchronous Serial Interface 0 (ESSI0)
Signal Description
2-15

Related parts for XC56309VF100A