ST16C550CJ44-F Exar Corporation, ST16C550CJ44-F Datasheet - Page 15

no-image

ST16C550CJ44-F

Manufacturer Part Number
ST16C550CJ44-F
Description
IC UART FIFO 16B SGL 44PLCC
Manufacturer
Exar Corporation
Type
UART with 16-byte FIFOsr
Datasheet

Specifications of ST16C550CJ44-F

Number Of Channels
1, UART
Package / Case
44-LCC (J-Lead)
Features
*
Fifo's
16 Byte
Voltage - Supply
2.97 V ~ 5.5 V
With False Start Bit Detection
Yes
With Modem Control
Yes
With Cmos
Yes
Mounting Type
Surface Mount
Data Rate
1.5 Mbps
Supply Voltage (max)
5.5 V
Supply Voltage (min)
2.97 V
Supply Current
3 mA
Maximum Operating Temperature
+ 70 C
Minimum Operating Temperature
0 C
Mounting Style
SMD/SMT
Operating Supply Voltage
3.3 V, 5 V
No. Of Channels
1
Supply Voltage Range
2.97V To 5.5V
Operating Temperature Range
0°C To +70°C
Digital Ic Case Style
PLCC
No. Of Pins
44
Filter Terminals
SMD
Rohs Compliant
Yes
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant, Lead free / RoHS Compliant
Other names
1016-1259-5

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
ST16C550CJ44-F
Manufacturer:
Exar Corporation
Quantity:
10 000
IER BIT-3:
Logic 0 = Disable the modem status register interrupt.
(normal default condition)
Logic 1 = Enable the modem status register interrupt.
IER BIT 4-7: Not used and set to “0”.
FIFO Control Register (FCR)
This register is used to enable the FIFO’s, clear the
FIFO’s, set the transmit/receive FIFO trigger levels,
and select the DMA mode. The DMA, and FIFO
modes are defined as follows:
DMA MODE:
FCR BIT-0:
Logic 0 = Disable the transmit and receive FIFO.
(normal default condition)
Logic 1 = Enable the transmit and receive FIFO. This
bit must be a “1” when other FCR bits are written to or
they will not be programmed.
FCR BIT-1:
Logic 0 = No FIFO receive reset. (normal default
condition)
Logic 1 = Clears the contents of the receive FIFO and
resets the FIFO counter logic (the receive shift regis-
ter is not cleared or altered). This bit will return to a
logic 0 after clearing the FIFO.
FCR BIT-2:
Logic 0 = No FIFO transmit reset. (normal default
condition)
Logic 1 = Clears the contents of the transmit FIFO and
resets the FIFO counter logic (the transmit shift regis-
ter is not cleared or altered). This bit will return to a
logic 0 after clearing the FIFO.
FCR BIT-3:
Logic 0 = Set DMA mode “0”. (normal default condi-
tion)
Logic 1 = Set DMA mode “1.”
Transmit operation in mode “0”:
When the ST16C550 is in the ST16C450 mode
(FIFO’s disabled, FCR bit-0 = logic 0) or in the FIFO
mode (FIFO’s enabled, FCR bit-0 = logic 1, FCR bit-
Rev. 5.01
See description and DMA tables on page 11.
15
3 = logic 0) and when there are no characters in the
transmit FIFO or transmit holding register, the -
TXRDY pin will be a logic 0. Once active the -TXRDY
pin will go to a logic 1 after the first character is loaded
into the transmit holding register.
Receive operation in mode “0”:
When the ST16C550 is in mode “0” (FCR bit-0 = logic
0) or in the FIFO mode (FCR bit-0 = logic 1, FCR bit-
3 = logic 0) and there is at least one character in the
receive FIFO, the -RXRDY pin will be a logic 0. Once
active the -RXRDY pin will go to a logic 1 when there
are no more characters in the receiver.
Transmit operation in mode “1”:
When the ST16C550 is in FIFO mode ( FCR bit-0 =
logic 1, FCR bit-3 = logic 1 ), the -TXRDY pin will be
a logic 1 when the transmit FIFO is completely full. It
will be a logic 0 if one or more FIFO locations are
empty.
Receive operation in mode “1”:
When the ST16C550 is in FIFO mode (FCR bit-0 =
logic 1, FCR bit-3 = logic 1) and the trigger level has
been reached, or a Receive Time Out has occurred,
the -RXRDY pin will go to a logic 0. Once activated, it
will go to a logic 1 after there are no more characters
in the FIFO.
FCR BIT 4-5: Not used.
FCR BIT 6-7: These bits are used to set the trigger level
for the receive FIFO interrupt.
An interrupt is generated when the number of characters
in the FIFO equals the programmed trigger level. How-
ever the FIFO will continue to be loaded until it is full.
BIT-7
1
0
0
1
BIT-6
0
1
0
1
RX FIFO trigger level
ST16C550
14
1
4
8

Related parts for ST16C550CJ44-F