X09-009PKI-RA Digi International, X09-009PKI-RA Datasheet - Page 12

MOD RF 900MHZ 19.2K RS232/485 IN

X09-009PKI-RA

Manufacturer Part Number
X09-009PKI-RA
Description
MOD RF 900MHZ 19.2K RS232/485 IN
Manufacturer
Digi International
Series
XStream™r
Datasheets

Specifications of X09-009PKI-RA

Function
Transceiver, FHSS
Modulation Or Protocol
FHSS, FSK
Frequency
900MHz
Applications
ISM
Interface
RS-232, RS-485
Sensitivity
-110dBm
Power - Output
20dBm (100mW)
Data Rate - Maximum
10 kbps
Voltage - Supply
7 V ~ 18 V
Package / Case
Module
Wireless Frequency
900 MHz
Interface Type
SMA
Modulation
FHSS
Operating Temperature Range
- 40 C to + 85 C
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Features
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
Q4542190
3. RF Modem Operation 
© 2006 MaxStream, Inc. Confidential & Proprietary 
XStream‐PKG‐R™ RS‐232/485 RF Modem – Product Manual v5.x00 [2006.02.24] 
3.1. Serial Communications
3.1.1. RS-232 and RS-485/422 Data Flow
3.1.2. Host and RF Modem I/O Settings
Devices that have a UART interface can connect directly through the pins of the XStream Modem
as is shown in the figure below.
Figure 3.1. System Data Flow Diagram in a UART‐interfaced environment  
Serial communications between a host and an XStream RF Modem are dependent upon having
matching baud rate, parity, stop bit & number of data bits settings. Failure to enter the modem
into AT Command Mode is most commonly due to baud rate mismatch. Refer to the table below
to ensure host serial port settings match those of the modem.
Table 3.1. Parameter values critical to serial communications between the RF Modem and host 
Parameter Setting
Baud (Serial Data Rate)
Number of Data Bits
Parity
Number of Stop Bits
Both the XStream RF Modem and host (PC) settings can be viewed and adjusted using
MaxStream’s proprietary X-CTU Software. Use the “PC Settings” tab to configure host settings.
Use the “Terminal” or “Modem Configuration” tabs to configure the RF Modem settings. Refer to
the RF Modem Configuration sections for more information [p21].
(Low‐asserted signals distinguished with horizontal line over signal name.) 
 
XStream RF Modem Default Parameter Value
9600 bps or 19200 baud (Factory-set RF data rates)
8
None
1
(NB parameter = 0)
(NB parameter = 0)
(NB parameter = 0)
 
           12 