XBP24-ACI-001 Digi International/Maxstream, XBP24-ACI-001 Datasheet - Page 42

no-image

XBP24-ACI-001

Manufacturer Part Number
XBP24-ACI-001
Description
MODULE 802.15.4 100MW CHIP ANT
Manufacturer
Digi International/Maxstream
Series
XBEE-PRO™r
Datasheets

Specifications of XBP24-ACI-001

Frequency
2.4GHz
Data Rate - Maximum
250kbps
Modulation Or Protocol
802.15.4
Applications
Home/Building Automation, Industrial Control, ZigBee™
Power - Output
20dBm (100mW)
Sensitivity
-100dBm
Voltage - Supply
2.8 V ~ 3.4 V
Current - Receiving
55mA
Current - Transmitting
215mA @ 3.3V
Data Interface
PCB, Through Hole
Antenna Connector
On-Board, Chip
Operating Temperature
-40°C ~ 85°C
Package / Case
Module
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Memory Size
-
XBee®/XBee‐PRO®  RF Modules ‐ 802.15.4 ‐ v1.xEx [2009.09.23]
D7 (DIO7 Configuration) Command
D8 (DI8 Configuration) Command
DA (Force Disassociation) Command
DB (Received Signal Strength) Command
DH (Destination Address High) Command
<I/O Settings> The D7 command is used to
select/read the behavior of the DIO7 line (pin 12).
Options include:
<I/O Settings> The D8 command is used to
select/read the behavior of the DI8 line (pin 9).
This command enables configuring the pin to
function as a digital input. This line is also used
with Pin Sleep.
<(Special)> The DA command is used to immedi-
ately disassociate an End Device from a Coordi-
nator and reattempt to associate.
<Diagnostics> DB parameter is used to read the
received signal strength (in dBm) of the last RF
packet received. Reported values are accurate
between -40 dBm and the RF module's receiver
sensitivity.
Absolute values are reported. For example: 0x58 = -88 dBm (decimal). If no packets have been
received (since last reset, power cycle or sleep event), “0” will be reported.
<Networking {Addressing}> The DH command is
used to set and read the upper 32 bits of the RF
module's 64-bit destination address. When com-
bined with the DL (Destination Address Low)
parameter, it defines the destination address used
for transmission.
An module will only communicate with other
modules having the same channel (CH parame-
ter), PAN ID (ID parameter) and destination address
(DH + DL parameters).
© 2009 Digi Internatonal, Inc.
• CTS flow control
• Analog-to-digital converter
• Digital input
• Digital output
• RS485 TX Enable (this output is 3V CMOS
level, and is useful in a 3V CMOS to RS485
conversion circuit)
AT Command: ATDA
Minimum Firmware Version Required: v1.x80
AT Command: ATDH
Parameter Range: 0 - 0xFFFFFFFF
Default Parameter Value: 0
Related Commands: DL (Destination Address
Low), CH (Channel), ID (PAN VID), MY (Source
Address)
AT Command: ATDB
Parameter Range [read-only]:
0x17-0x5C (XBee), 0x24-0x64 (XBee-PRO)
AT Command: ATD7
Parameter Range:0 - 5
Default Parameter Value:1
Parameters 3-7 supported as of firmware
version 1.x.A0
AT Command: ATD8
Parameter Range:0 - 5
Default Parameter Value:0
Minimum Firmware Version Required: 1.xA0
Parameter
Parameter
0
1
2
3
4
5
6
7
0
3
(1, 2, 4 & 5 n/a)
RS485 TX Enable High
RS485 TX Enable Low
CTS Flow Control
Configuration
Configuration
Disabled
Disabled
DO high
DO low
n/a
DI
DI
     42