XBP24-ACI-001 Digi International/Maxstream, XBP24-ACI-001 Datasheet - Page 63

no-image

XBP24-ACI-001

Manufacturer Part Number
XBP24-ACI-001
Description
MODULE 802.15.4 100MW CHIP ANT
Manufacturer
Digi International/Maxstream
Series
XBEE-PRO™r
Datasheets

Specifications of XBP24-ACI-001

Frequency
2.4GHz
Data Rate - Maximum
250kbps
Modulation Or Protocol
802.15.4
Applications
Home/Building Automation, Industrial Control, ZigBee™
Power - Output
20dBm (100mW)
Sensitivity
-100dBm
Voltage - Supply
2.8 V ~ 3.4 V
Current - Receiving
55mA
Current - Transmitting
215mA @ 3.3V
Data Interface
PCB, Through Hole
Antenna Connector
On-Board, Chip
Operating Temperature
-40°C ~ 85°C
Package / Case
Module
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Memory Size
-
XBee®/XBee‐PRO®  RF Modules ‐ 802.15.4 ‐ v1.xEx [2009.09.23]
MSB (most significant byte) first,
LSB (least significant) last
MSB (most significant byte) first,
LSB (least significant) last
Source Address (Bytes 5-6)
Source Address (Bytes 5-12)
Start Delimiter
Start Delimiter
0x7E
0x7E
TX (Transmit) Status
RX (Receive) Packet: 64-bit Address
RX (Receive) Packet: 16-bit Address
API Identifier Value: 0x89
When a TX Request is completed, the module sends a TX Status message. This message will indi-
cate if the packet was transmitted successfully or if there was a failure.
Figure 3‐15. TX Status Frames
NOTES:
API Identifier Value: 0x80
When the module receives an RF packet, it is sent out the UART using this message type.
Figure 3‐16. RX Packet (64‐bit address) Frames
API Identifier Value: 0x81
When the module receives an RF packet, it is sent out the UART using this message type.
Figure 3‐17. RX Packet (16‐bit address) Frames
© 2009 Digi Internatonal, Inc.
• “STATUS = 1” occurs when all retries are expired and no ACK is received.
• If transmitter broadcasts (destination address = 0x000000000000FFFF), only
• “STATUS = 3” occurs when Coordinator times out of an indirect transmission.
MSB
MSB
Received Signal Strength Indicator -
Hexadecimal equivalent of (-dBm) value.
(For example: If RX signal strength = -40
dBm, “0x28” (40 decimal) is returned)
Received Signal Strength Indicator -
Hexadecimal equivalent of (-dBm) value.
(For example: If RX signal strength = -40
dBm, “0x28” (40 decimal) is returned)
“STATUS = 0 or 2” will be returned.
Timeout is defined as (2.5 x SP (Cyclic Sleep Period) parameter value).
Length
Length
LSB
LSB
API Identifier
API Identifier
0x81
0x80
Start Delimiter
RSSI (Byte 13)
RSSI (Byte 7)
0x7E
API-specific Structure
API-specific Structure
Identifies UART data frame being reported.
Note: If Frame ID = 0 in the TX Request, no
AT Command Response will be given.
Frame Data
Frame Data
Identifier-specific Data
Identifier-specific Data
MSB
cmdData
cmdData
Length
Frame ID (Byte 5)
LSB
API Identifier
0x89
Checksum
Checksum
1 Byte
1 Byte
bit 0 [reserved]
bit 1 = Address broadcast
bit 2 = PAN broadcast
bits 3-7 [reserved]
bit 0 [reserved]
bit 1 = Address broadcast
bit 2 = PAN broadcast
bits 3-7 [reserved]
API-specific Structure
Options (Byte 14)
Frame Data
Options (Byte 8)
Identifier-specific Data
cmdData
0 = Success
1 = No ACK (Acknowledgement) received
2 = CCA failure
3 = Purged
Checksum
1 Byte
Up to 100 Bytes per packet
Up to 100 Bytes per packet
RF Data (Byte(s) 15-n)
Status (Byte 6)
RF Data (Byte(s) 9-n)
     63