X09-019WNI Digi International/Maxstream, X09-019WNI Datasheet - Page 21

no-image

X09-019WNI

Manufacturer Part Number
X09-019WNI
Description
MODULE XSTREAM RF OEM 900MHZ
Manufacturer
Digi International/Maxstream
Series
XStream™r
Datasheets

Specifications of X09-019WNI

Frequency
900MHz
Data Rate - Maximum
19.2kbps
Modulation Or Protocol
FSK
Power - Output
100mW
Sensitivity
-110dBm
Voltage - Supply
5V
Current - Receiving
50mA
Current - Transmitting
140mA
Data Interface
Connector, 11 Pin Header, 1 mm Pitch
Antenna Connector
On-Board, Wire Antenna
Operating Temperature
0°C ~ 70°C
Package / Case
Module
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Applications
-
Memory Size
-
Other names
Q4224981
XStream™ OEM RF Module – Product Manual v5.x00 [2006.02.24] 
BK (Serial Break Passing) Command
BO (Serial Break Timeout) Command
BT (Guard Time Before) Command
CB (Connection Duration Timeout) Command
CC (Command Sequence Character) Command
<Serial Interfacing> Pass a serial break condition
on the DI pin to the DO pin of another module.
<Serial Interfacing> DO pin will return to default
after no serial break status information is
received during the timeout period.
Use with BK parameter = 1.
<Command Mode Options> BT Command is used
to set the DI pin silence time that must precede
the command sequence character (CC
Command) of the AT Command Mode Sequence.
Refer to the AT Commands section [p16] to view
the default AT Command Mode sequence.
<Networking & Security> Set/Read the
maximum amount of time an exclusive
connection between a base and remote module
in a point-to-multipoint network is sustained. The
remote module will disconnect when this timeout
expires.
<Command Mode Options> CC Command is used
to set the ASCII character to be used between
Guard Times of the AT Command Mode Sequence
(BT+ CC + AT). The AT Command Mode
Sequence activates AT Command Mode (from
Idle Mode).
Refer to the AT Commands section [p16] to view
the default AT Command Mode sequence.
   © 2006 MaxStream, Inc. Confidential and Proprietary 
AT Command: ATBK
Binary Command: 0x2E (46 decimal)
Parameter Range: 0 – 1
Default Parameter Value: 0
Number of bytes returned: 1
Related Commands: BO (Serial Break Timeout)
Minimum Firmware Version Required: 4.30
AT Command: ATBO
Binary Command: 0x30 (48 decimal)
Parameter Range: 0 – 0xFFFF [x 1 second]
Default Parameter Value: 0
Number of bytes returned: 2
Related Commands: BK (Serial Break Passing)
Minimum Firmware Version Required: 4.30
AT Command: ATBT
Binary Command: 0x04 (4 decimal)
Parameter Range: 0 – 0xFFFF
Default Parameter Value: 0x0A (10 decimal)
Number of bytes returned: 2
Related Commands: AT (Guard Time After), CC
(Command Sequence Character)
AT Command: ATCB
Binary Command: 0x33 (51 decimal)
Parameter Range: 0x01 – 0xFFFF
Default Parameter Value: 0x28 (4d seconds)
Number of bytes returned: 2
Related Commands: CE (Connection Inactivity
Timeout), DC (Disconnect), MD (RF Mode)
Minimum Firmware Version Required: 4.30
AT Command: ATCC
Binary Command: 0x13 (19 decimal)
Parameter Range: 0x20 – 0x7F
Default Parameter Value: 0x2B (ASCII “+” sign)
Number of bytes returned: 1
Related Commands: AT (Guard Time After), BT
(Guard Time Before)
Parameter
0
1
[x 100 milliseconds]
[x 100 milliseconds]
Configuration
disable
enable
21 