X09-019WNI Digi International/Maxstream, X09-019WNI Datasheet - Page 62

no-image

X09-019WNI

Manufacturer Part Number
X09-019WNI
Description
MODULE XSTREAM RF OEM 900MHZ
Manufacturer
Digi International/Maxstream
Series
XStream™r
Datasheets

Specifications of X09-019WNI

Frequency
900MHz
Data Rate - Maximum
19.2kbps
Modulation Or Protocol
FSK
Power - Output
100mW
Sensitivity
-110dBm
Voltage - Supply
5V
Current - Receiving
50mA
Current - Transmitting
140mA
Data Interface
Connector, 11 Pin Header, 1 mm Pitch
Antenna Connector
On-Board, Wire Antenna
Operating Temperature
0°C ~ 70°C
Package / Case
Module
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Applications
-
Memory Size
-
Other names
Q4224981
XStream™ OEM RF Module – Product Manual v5.x00 [2006.02.24] 
X-CTU Software
Using the X-CTU Software
Se ial Communications Software
X-CTU is MaxStream-provided software used to interface with and configure XStream OEM RF
M
F
Install X-CTU software
Dou
loca ed in the ‘software’ folder of the MaxStream CD and also under the ‘Downloads’ sectio
the following web page:
Setup
To use the X-CTU software, a module assembly (XStream Module mounted to a MaxStream XIB-
R
settings of the serial port (“PC Settings” tab) m
a
r
A terminal program is built into the X-CTU Software. Other terminal programs such as
“H
i
Figure
N
The exa
To save the new value to the module’s non-volatile (long term) memory, issue WR (Write)
Command after modifying parameters.
   © 2006 MaxStream, Inc. Confidential and Proprietary 
nterface, use the following syntax:
igure B‐24    X‐CTU User Interface (PC Settings, Range Test, Terminal and Modem Configuration tabs) 
nd NB (Parity) Commands).
-R Interface Board) must be connected to the serial port of a PC. The data rate and parity
OTE: To read a parameter value stored in a register, leave the parameter field blank.
odules. The software application is organized into the following four tabs:
yperTerminal” can also be used. When issuing AT Commands through a terminal program
• PC Settings tab - Setup PC serial ports to interface with an XStream Module assembly
• Range Test tab – Test XStream Module's range and monitor packets sent and received
• Terminal tab – Set and read XStream Module parameters using AT Commands
• Modem Configuration tab – Set and read XStream Module parameters
ble-click the "setup_X-CTU.exe" file and follow prompts of the
t
 B‐25    Syntax for sending AT Commands: 
mple above issues DT Command to change destination address of the module to “0x1F”.
http://www.maxstream.net/helpdesk/download.php
ust match those of the module (BD (Baud Rate)
installation screens. This file is
n of
62 