X09-019WNI

Manufacturer Part Number
X09-019WNI
Description
MODULE XSTREAM RF OEM 900MHZ
Manufacturer
Digi International/Maxstream
Series
XStream™r
Datasheets

Specifications of X09-019WNI

Frequency
900MHz
Data Rate - Maximum
19.2kbps
Modulation Or Protocol
FSK
Power - Output
100mW
Sensitivity
-110dBm
Voltage - Supply
5V
Current - Receiving
50mA
Current - Transmitting
140mA
Data Interface
Connector, 11 Pin Header, 1 mm Pitch
Antenna Connector
On-Board, Wire Antenna
Operating Temperature
0°C ~ 70°C
Package / Case
Module
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Applications
-
Memory Size
-
Other names
Q4224981
XStream™ OEM RF Module – Product Manual v5.x00 [2006.02.24] 
HT (Time before Wake-up Initializer) Command
ID (Modem VID) Command
IU (DI2, DI3 Update Timer) Command
<Sleep (Low Power)> If any modules within
range are running in a “Cyclic Sleep” setting, a
wake-up initializer must be used by the
transmitting module for sleeping modules to
remain awake [refer to the LH (“Wake-up
Initializer Timer”) Command]. When a receiving
module in Cyclic Sleep wakes, it must detect the
wake-up initializer in order to remain awake and
receive data. The value of HT Parameter tells the
transmitter, “After a period of inactivity (no
transmitting or receiving) lasting HT amount of time, send a long wake-up initializer”. HT
Parameter should be set to match the inactivity timeout [specified by ST (Time before Sleep)
Command] used by the receiver(s).
From the receiving module perspective, after HT time elapses and the inactivity timeout (ST
command) is met, the receiver goes into cyclic sleep. In cyclic sleep, the receiver wakes once per
sleep interval to check for a wake-up initializer. When a wake-up initializer is detected, the
module will stay awake to receive data. The wake-up initializer must be longer than the cyclic
sleep interval to ensure that sleeping modules detect incoming data. When HT time elapses, the
transmitter then knows that it needs to send a long Wake-up Initializer for all receivers to be able
to remain awake and receive the next transmission. Matching HT to the time specified by ST on
the receiving module guarantees that all receivers will detect the next transmission.
<Networking & Security> Set/Read the VID
(Vendor Identification Number). Only modules
with matching VIDs can communicate with each
other. Modules with non-matching VIDs will not
receive unintended data transmission.
<Serial Interfacing> Set/Read the interval at
which the status of DI2, DI3 and Break is
transmitted. Additionally, status is transmitted
whenever there is a transition. A setting of “0”
disables periodic update. DI2 or DI3 passing
must be enabled for the update to take place.
   © 2006 MaxStream, Inc. Confidential and Proprietary 
AT Command: ATIU
Binary Command: 0x3B (59 decimal)
Parameter Range: 0 - 0xFFFF [x 100 ms]
Default Parameter Value: 0x0A (10 decimal)
Number of bytes returned: 2
Related Commands: BK (Serial Break Passing),
BO (Serial Break Timeout), CO (DO3 Timeout),
DR (Disconnect), RT (DI2 Configuration), TO
(DO2 Timeout)
Minimum Firmware Version Required: 4.30
AT Command: ATHT
Binary Command: 0x03 (3 decimal)
Parameter Range: 0 – 0xFFFF
Default Parameter Value: 0xFFFF (means that
long wake-up initializer will not be sent)
Number of bytes returned: 2
Related Commands: LH (Wake-up Initializer
Timer), SM (Sleep Mode), ST (Time before
Sleep)
AT Command: ATID
Binary Command: 0x27 (39 decimal)
Parameter Range (user-settable):
(Factory-set and read-only) :
Number of bytes returned: 2
Minimum Firmware Version Required: 4.2B
(previous firmware versions did not support
user-settable IDs.)
[x 100 milliseconds]
0x10 - 0x7FFFF
0x8000 – 0xFFFF
26 

Related parts for X09-019WNI