E8M-A1 3M Omron, E8M-A1 3M Datasheet

no-image

E8M-A1 3M

Manufacturer Part Number
E8M-A1 3M
Description
SENSR PRESSR DIFFRENTL 0-.145PSI
Manufacturer
Omron
Series
E8Mr
Datasheet

Specifications of E8M-A1 3M

Pressure Type
Gauge
Operating Pressure
0.145 PSI, 1 kPa
Port Size
Male, 1/8" (3.175mm) 27 NPT
Output
Digital
Voltage - Supply
12 V ~ 24 V
Termination Style
Cable
Operating Temperature
0°C ~ 50°C
Package / Case
Module
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
E8M-A13M
E8MA13M
Four-channel Pressure Sensor Offers
Versatile Functions and High Precision
Without Errors
H
H
H
H
H
Ordering Information
J SENSORS
E8MS
E8M
J CONTROLLER
Type
Positive pressure sensor
Positive pressure sensor
Negative pressure sensor
Type
Minute differential pressure sensor
Positive pressure sensor
Negative pressure sensor
Item
Controller
Controller
Pressure Sensor
The industry’s smallest pressure sensor,
compact, lightweight — ideal for robot arms
or other moving components
A highly sensitive minute-pressure sensor
model detects very small differences in air
pressure
Requires no wiring conduit — can be
located for sensing in small places
Simple display panel efficiently saves
space, but offers large LEDs
Easy sensitivity adjustment using the teach
function and channel-to-channel copy
function
R
Pressure range description
0 to 100 kPa (0 to 14.5 psi)
0 to 1 MPa (0 to 145 psi)
0 to - - 101 kPa (0 to - - 14.6 psi)
Pressure range description
Differential pressure from 0 to 1,000 Pa
(0 to 0.145 psi) between positive and
negative ports
0 to 1 MPa (0 to 145 psi)
0 to - - 101 kPa (0 to - - 14.6 psi)
Description
Optional for pressure sensors:
Optional for pressure sensors:
E8M series and E8MS series
2
Part number
E8MS-01
E8MS-10
E8MS-N0
Part number
E8M-A1
E8M-10
E8M-N0
Part number
K3C-MP8-T1Z
K3C MP8 T1Z
E8M/E8MS

Related parts for E8M-A1 3M

E8M-A1 3M Summary of contents

Page 1

... Differential pressure from 0 to 1,000 0.145 psi) between positive and negative ports MPa (0 to 145 psi 101 kPa ( 14.6 psi) Description Optional for pressure sensors: Optional for pressure sensors: E8M series and E8MS series 2 E8M/E8MS Part number E8MS-01 E8MS-10 E8MS-N0 Part number ...

Page 2

... E8M/E8MS J ACCESSORIES (ORDER SEPARATELY) Item Description Sensor connector cable 4-pin connector with 3-m cable required for E8M-10 and E8M-N0 (Note: E8M-A1 does not require this cable.) 3-pin connector with 3-m cable required for E8MS-01, E8MS-10 and E8MS-N0 Cable connector Replacement cable connector for the E89-M3 and E89-M4 Sensor connector cables ...

Page 3

... NPT and M5 female screw Connector (use the E89-M3, sold separately) Approx (1.06 oz.) SUS304 Aluminum, polyether sulfonic resin Instruction manual Pressure generator 4 E8M/E8MS E8M- 101 kPa ( 14.6 psi) 400 kPa (58 psi) 2 (approx.10G) for 8 min for 4 times each male screw Approx (0.71 oz.) ...

Page 4

... Panel mounting Power supply and output: 7-pin terminal Sensor I/O: 4-pin connector Weight (packaged weight) Approx (3.17 oz.) Accessories Instruction manual, Adapter E8MS-01 E8MS-10 E8M- 100 kPa MPa (0 to 14.5 psi 145 psi max. 30 VDC max. 0.8 V max. with a flow current 0.4 V max. with a flow current (approx ...

Page 5

... E8MS-01 Pressure (kPa) E8MS-N0/E8M-N0 Pressure (kPa) J OUTPUT LINEARITY E8MS-01 Pressure (kPa) E8MS-N0/E8M-N0 E8MS-N0 E8M-N0 Pressure (kPa) E8MS-10/E8M-10 Pressure (kPa) E8M-A1 Differential pressure (Pa) between positive and negative ports E8MS-10/E8M-10 E8MS-10 E8M-10 Pressure (kPa) E8M-A1 Differential pressure (Pa) between positive and negative ports 6 E8M/E8MS ...

Page 6

... Rated pressure Voltage (V) E8M-10 Pressure 0 Rated pressure Voltage (V) E8MS-10 Pressure 0 Rated pressure Temperature (°C) E8M-10 Pressure 0 Rated pressure Temperature (°C) 7 E8M/E8MS E8MS-N0 Pressure 0 Rated pressure Voltage (V) E8M-N0 Pressure 0 Rated pressure Voltage (V) E8MS-N0 Pressure 0 Rated pressure Temperature (°C) E8M-N0 Pressure 0 Rated pressure ...

Page 7

... DISPLAY Used to select the measurement value, ON-point, or OFF- point display in measurement mode. Set menu or set value display is selected in set mode. 14. UP/Down Used to change the set values in set mode. The values increase by pressing the Up ( crease by pressing the Down ( 8 E8M/E8MS ) Key and de- ) Key. ...

Page 8

... E8M/E8MS Operation J OUTPUT CIRCUITS Sensor Output Configuration Linear Output E8MS-01, E8MS-10, E8MS-N0 Connector Brown Pressure Sensor main Black (linear output) circuit Load E8M-A1 Brown Power indicator (green) Pink Pressure Sensor main Black (linear output) circuit Load E8M-10, E8M-N0 Connector Brown Power ...

Page 9

... E8M/E8MS J DISPLAYS OF SETTINGS AND MEASUREMENTS Digital Display The E8M displays alphanumeric characters,such as measurement values and menu items, with 7-segment LEDs as shown below for example. Display Meaning ON and OFF-point Settings set Unit (kPa) kpa Width wid Average aUe J MODES In addition to a measurement value display function, the K3C has a variety of functions including an external device control function. ...

Page 10

... Special Setting Mode Key-protect function for set value protection Data copy function to copy the data of channels Original pressure fluctuation compensation setting Hysteresis width Window width setting Measurement value display refresh interval setting Number of measurement times setting for measurement value averaging 11 E8M/E8MS ...

Page 11

... Select the Sensor type according to the target object. The following Sensor types are available. Model E8M- E8MS- 101 E8M-N0 E8MS-10 1000 E8M-10 Not connected --- E8MS-01 100 Press the DISPLAY Key once. A Sensor type appears in the main display. Press the DISPLAY A preset Sensor type appears. Key once. ...

Page 12

... E8MS- 101 kPa Yes E8M-N0 E8MS- MPa Yes E8M-10 E8M- 1,000 Pa Yes E8MS- 100 kPa Yes Note: Select Uol for voltage display. J OUTPUT CONTROL The K3C has output according to the measurement value. The output can be used to control external devices, such as valves and absorption systems ...

Page 13

... Set ON- and OFF-points for each channel. Note: 1. The output method varies with the ON and OFF-point settings. 2. When using the E8M-A1 Minute Differential Pressure Sensor, both the ON point and OFF point must be set to the negative setting. (They cannot be set to the positive setting.) The Controller will be in hysteresis mode if the ON-point set • ...

Page 14

... Pressure OFF point of OUT1 Press the Up or Down Key to change the set value. ON point of OUT2 Press the Up or Down Key to change the set value. Enter OFF point of OUT1 Press the Up or Down Key to change the set value. 15 E8M/E8MS ...

Page 15

... When the OUT1 settings are finished and the DISPLAY Key is pressed, OUT2 will be ready for setting only with the channel that has OUT2 output. Channel 1 Cancel Select with the Up or Down Key. Channels Cancel Select with the Up or Down Key. Window Mode NO output NC output Enter Select with the Up or Down Key. Enter 16 E8M/E8MS OFF point OFF point - - - Hysteresis ON point ON point - - - Hysteresis ...

Page 16

... If there is no key input for 2 s during set value display, the display panel will automatically return to the measurement value display. Channel 1 (In the Case of Example 1 on Page 15) ON point of OUT1 OFF point of OUT2 Channels (In the Case of Example 2 on page 15) ON point of OUT1 OFF point of OUT1 ON point of OUT2 OFF point of OUT1 17 E8M/E8MS ...

Page 17

... PLAY Key. By pressing the DISPLAY Key again, OUT2 will be ready for setting for channel 1 only. Two-point teaching mode One-point teaching mode (hysteresis mode teaching) (window mode teaching) Displayed items: TH1 (teach hysteresis mode, first point) TW (teach window mode) Two-point Teaching Pressure 18 E8M/E8MS ...

Page 18

... Note: The Controller will be in hysteresis mode automatically after two-point teaching. The above settings are useful for applications that check vacuum absorption. ON-point and Present OFF-point indicators measurement value flash. appears. Present measurement value appears. Teaching completed on the first point. Measurement mode Teaching completed on the second point. 19 E8M/E8MS ...

Page 19

... The present measurement value will be reset as zero by pressing the RST/ESC Key for 1 s. The possible zero-reset range is within ± the rated output. Otherwise, “ER.T” will appear and the present measurement value will not be reset. Press the RST/ESC Key for 1 s. Measurement mode Teaching completed. 20 E8M/E8MS ...

Page 20

... No key protect 1: No key protect in SET, UNT, zero-reset, or teaching operation, zero-reset, and all set modes. 2: Key protect in teaching operation. Hysteresis Original Fluctua- Width Change tion Compensa- Function tion Function Window Width Setting 21 E8M/E8MS Cancel Edit Use the Up or Down Key. ...

Page 21

... If the contents of channels are copied to channel 1, there will be no difference in data be- tween OUT1 and OUT2 of channel 1. Source channel appears. Destination channel appears. Copying Source channel change with the Up or Down Key. Execute copy Destination channel change with the CH Key. 22 E8M/E8MS ...

Page 22

... The width between the ON and OFF points are used as the hysteresis width in hysteresis mode. Therefore, the settings cannot be changed in the above steps pressing the DISPLAY Key after OUT1 is displayed, the display will change to OUT2 only with the channel that has OUT2 output. Enter Window Mode Changinghysteresis width Pressure ON point OFF point 23 E8M/E8MS ...

Page 23

... The set value will be entered and “AVE” will appear by pressing the MENU Key. If the RST/ESC Key is pressed, set value change will be canceled and “DSP” will appear. Note: The number of measurement times for measurement value averaging is set in the menu while “AVE” is displayed. Enter Enter 24 E8M/E8MS ...

Page 24

... Note: If 0.5 is set while “DSP” is displayed and 32 is set while “AVE” is displayed, pressure will be measured 32 times and averaged as a block. The averaged blocks as a mean value will be displayed and refreshed every 0.5 s. Cancel Value change with the Up or Down Key. Enter Enter 25 E8M/E8MS ...

Page 25

... Error code flashes. error Dimensions Unit: mm (inch) J SENSORS E8MS-01 M5, 7.5-mmdepth E8MS-10 E8MS-N0 15 (0.59) 13 (0.51) E8M-A1 4-mm-dia., 4-conductor (40 strands x 0.08 dia.), vinyl-insulated cord, length Error code Reset method Reset the power supply. err None Automatically reset when the input returns to the specified range. ...

Page 26

... E89-M3 Sensor I/O Connector Cable for E8M (Sold separately) Includes one XS8A-0442 cable Connector. E89-M4 Sensor I/O Connector Cable for E8MS (Sold separately) Includes one XS8A-0442 cable Connector. 8.9 (0.35) Connection with E89-M3 Sensor I/O Connector ...

Page 27

... E8M/E8MS XS8A-0442 Cable Connector (One Connector is Supplied with the E8M-A1) 7 (0.28) 16.1 (0.63) 2.5 10.2 (0.10) (0.40) 3.2 (0.13) One XS8A-0442 Cable Connector is provided with the E89-M3 and E89-M4 Sensor Connector Cable. Refer to the Ordering Information section for replacement orders. J CONTROLLER ...

Page 28

... Use the Pressure Controllers in the following combinations. The E89-M3/M4 is required when using the Sensor as a single unit. Model E8MS-01 E8MS-10 E8MS-N0 E8M-A1 E8M-10 E8M-N0 Note: f: Required; ×: Not required. Sensor and Controller Connection E8MS-jj E8M-10/N0 29 E8M/E8MS No clearance allowed (1) (2) E89-M3 E89-M4 K3C-MP8-T1Z K32-MP2W K3C-DP8-T1Z × ...

Page 29

... J APPLICATIONS You must allow sufficient leeway in ratings and performance and provide proper fail-safe and other safety measures when using the Link the E8M in any of the following applications. Be sure also to consult with your OMRON representative before actually attempt- ing any of these applications. ...

Page 30

... E8M/E8MS E8MS-jj/E8M-10 The pressure-introducing section (aluminum for E8MS, SUS304 for E8M) is fixed with tapered 1/8 NPT male screws and M5 female screws. When using tapered screws, use tapered 1/8 NPT female screws. Wrap the tapered 1/8 NPT male screws with sealing tape to prevent any leakage ...