Description
SENSR PRESSR DIFFRENTL 0-.145PSI
Manufacturer
Omron
Series
E8Mr
Datasheet

Specifications of E8M-A1 3M

Pressure Type
Gauge
Operating Pressure
0.145 PSI, 1 kPa
Port Size
Male, 1/8" (3.175mm) 27 NPT
Output
Digital
Voltage - Supply
12 V ~ 24 V
Termination Style
Cable
Operating Temperature
0°C ~ 50°C
Package / Case
Module
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
E8M-A13M
E8MA13M
Nomenclature
J PRESSURE SENSOR CONTROLLER
K3C Controller
Display Panel
1. Numeric and Menu Display (Main Display)
2. Unit Indicator
3. Sensor Indicator
4. OUT1 Indicator
5. OUT2 Indicator
6. ON-point Indicator (See Output Control in the Operation
7. Channel Display
8. OFF-point Indicator
E8M/E8MS
6
7
8
9
Indicates measurement values and setting menu items.
(Red)
Indicates the unit used for sensing. The unit indicated on the
indicator is the one currently set. (Green)
Indicates the operating conditions of Sensors connected to
the K3C. When the Sensors are in operation, corresponding
indicators are lit. (Green)
Sensors can be connected to channels 1 to 4. Channel 1 has
two outputs.
Lit when OUT1 is turned ON. (Orange)
Lit when OUT2 is turned ON. (Orange)
Section.)
The ON-point value presently set is displayed in the main
display when the ON-point indicator is lit.
Displays the channel of a Sensor to be in operation or where
data is being set. Channels 1 through 4 are available.
(Green)
The OFF-point value presently set is displayed in the main
display when the OFF-point indicator is lit. (Orange)
10
11
12
1
13
8
Operation Keys
9. CH
10. RST/ESC
11. TEACH
12. MENU
13. DISPLAY
14. UP/Down
2
3
4
5
14
Used to select the channel of a Sensor to be in operation or
where menu items are set. A channel is selected in sequence
1 to 4 by repeatedly pressing the CH Key.
Used to return to the previous menu. If the RST/ESC Key is
pressed right after a set value change, the new set value will
be canceled and the display will return to the previous menu.
The Controller will be zero-reset if the RST/ESC Key is
pressed for 1 s minimum.
Used for teaching settings.
Used to select the measurement mode or set mode, to
change menu items in set mode, and to enter set values.
Used to select the measurement value, ON-point, or OFF-
point display in measurement mode.
Set menu or set value display is selected in set mode.
Used to change the set values in set mode.
The values increase by pressing the Up (
crease by pressing the Down (
) Key.
) Key and de-