E8M-A1 3M Omron, E8M-A1 3M Datasheet - Page 28

no-image

E8M-A1 3M

Manufacturer Part Number
E8M-A1 3M
Description
SENSR PRESSR DIFFRENTL 0-.145PSI
Manufacturer
Omron
Series
E8Mr
Datasheet

Specifications of E8M-A1 3M

Pressure Type
Gauge
Operating Pressure
0.145 PSI, 1 kPa
Port Size
Male, 1/8" (3.175mm) 27 NPT
Output
Digital
Voltage - Supply
12 V ~ 24 V
Termination Style
Cable
Operating Temperature
0°C ~ 50°C
Package / Case
Module
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
E8M-A13M
E8MA13M
Installation
J ASSEMBLY PROCEDURE
For the E89-M3/M4 Sensor I/O Connector Cable (Sold
Separately) and XS8A-0442 Cable Connector (Pro-
vided with Sensor)
1. Processing the Sensor I/O Connector Cable End
The cable end is semi-stripped.
Cut the ends as shown in the following illustration, and do not
peel the shield.
2. Fitting Controller Conductors to Cable Connector Cover
Terminal numbers are engraved on the cover. Refer to the
following and be sure that these terminal numbers correspond to
the wire colors correctly.
Note: Pin 2 will be empty when the E89-M4 is mounted.
Check again that the terminal numbers correspond to the wire
colors correctly. Then, insert the cover into the plug connector.
Be sure that the cover is fully inserted into the plug connector.
3. Connecting Wires to Plug Connector
Tentatively place the wired cover on the plug connector.
Press the cover and fit the wires. Pliers can be used, in which
case, apply the pliers to the middle part of the cover and press
the cover as straight as possible against the plug connector.
E8M/E8MS
Semi-stripped
1
2
3
4
Terminal
Terminal
20 min
N
No.
(0.79)
(1.18)
30
50 (1.97)
Plug connector
Black (Output)
---
Brown (Vcc)
Blue (GND)
E89-M4
10 (0.39)
I/O code
Terminal number
Cover
Pink
(LED lighting input)
E89-M3
29
Be sure that there is no space between the cover and plug
connector.
Check through the window of the cover that the wires are fitted to
the plug connector properly.
Once attached to the plug connector, the cover and plug
connector cannot be reused. Before using the pliers to attach the
cover, be sure that the terminal numbers correspond to the wire
colors correctly. If the wires are connected to the plug connector
incorrectly, use a new cable connector.
4. Connecting/Disconnecting Controller Connector to/from the
Be sure that terminal number 1 engraved on the cable connector
is facing upwards (i.e., on the lock-lever side) and press the
cable connector against the socket connector until the cable
connector snaps in place.
Lift up the lock lever before disconnecting the plug connector.
Sensor and Controller Combinations
Use the Pressure Controllers in the following combinations. The
E89-M3/M4 is required when using the Sensor as a single unit.
Note:
Sensor and Controller Connection
E8MS-01
E8MS-10
E8MS-N0
E8M-A1
E8M-10
E8M-N0
Model
K3C-MP8-T1Z Four-channel Pressure Controller
E8MS-jj
E8M-10/N0
f: Required; ×: Not required.
×
×
×
×
f
f
E89-M3
E8M-A1
E89-M3/M4
f
f
f
×
×
×
E89-M4
(1)
No clearance allowed
K3C-MP8-T1Z
f
f
f
f
f
f
K3C-DP8-T1Z
K3C
(2)
E8M/E8MS
K32-MP2W
f
f
f
f
f
f
K32-MP2W

Related parts for E8M-A1 3M