XRT82D20IW Exar Corporation, XRT82D20IW Datasheet - Page 4

no-image

XRT82D20IW

Manufacturer Part Number
XRT82D20IW
Description
IC LIU EI SGL 28SOJ
Manufacturer
Exar Corporation
Datasheet

Specifications of XRT82D20IW

Product
Framer
Lead Free Status / RoHS Status
Contains lead / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
XRT82D20IW
Manufacturer:
N/A
Quantity:
20 000
Part Number:
XRT82D20IW-F
Manufacturer:
EXAR
Quantity:
519
Part Number:
XRT82D20IW-F
Manufacturer:
EXAR/艾科嘉
Quantity:
20 000
XRT82D20
SINGLE CHANNEL E1 LINE INTERFACE UNIT
PIN DESCRIPTIONS
P
10
IN
1
2
3
4
5
6
7
8
9
#
RNEG/LCV
S
ClkLOS
TNEG/
RPOS/
CODE
TPOS/
RLoop
RData
LLoop
RLOS
TData
YMBOL
RClk
TClk
T
YPE
O
O
O
O
O
I
I
I
I
I
Receiver Loss of Signal: This pin toggles Low to indicate the loss of signal at the
receive inputs.
Receiver Loss of Clock: With MuteRx=1, this pin will toggle low to indicate a loss
of clock has occurred when the receive signal is lost (RLOS=0). When RLOS=0, no
transitions occur on RClk, RPOS/RData and RNEG outputs.
Transmitter Negative Data Input/Coding Select: With Jitter Attenuator enabled
(pin 18=1), input activity on this pin determines whether the device is configured to
operate in single-rail or dual-rail mode. With n-rail transmit data applied to this pin,
the device is automatically configured to operate in dual-rail mode for both transmit
input and receive output.
If this pin is tied high for more than 16 clock cycles, the device is configured to oper-
ate in single-rail mode with HDB3 encoding and decoding functions enabled.
If this pin is tied low for more than 16 clock cycles, the device is configured to oper-
ate in single-rail mode with AMI encoding and decoding functions enabled. (internal
pull-down).
Receive Negative Data/Line Code Violation Output:
If the device is configured in Dual-rail mode with n-rail data applied to pin 3, then the
receive negative data will be output through this pin.
If the device is configured in Single-rail mode and operate with HDB3 coding
enabled, HDB3 code violation will be detected and cause this pin to go high.
If the device is configured in Single-rail mode and with AMI coding selected, every
bipolar violation will be reported at this pin.
Receive Clock:
Output receive clock signal to the terminal equipment.
Receive Positive/ Data Output:
In Dual-rail mode, this signal is the p-rail receive output data. In Single-rail mode,
this signal is the receive output data.
Transmitter Clock Input:
Input clock signal (2.048 MHz ± 50ppm)
Transmit Positive / Data Input:
In Dual-rail mode, this signal is the p-rail transmit input data. In Single-rail mode,
this signal is the transmit input data.
Local Loop back enable (active low):
Tie this pin low to enable analog Local Loop-back.In local loop-back mode, transmit
output data is looped back to the input of the receiver.Input signal at RTIP and
RRing are ignored. Local Loop-back has priority over Remote and Digital Loop-
back mode. See
for more details. (internal pull-up).
Remote Loop Back Enable (active low):
Connect this pin to ground to enable Remote Loop-back. In Remote Loop-back
mode, transmit data at TPOS/TData and TNEG are ignored. See
The Remote Loop Back Mode” on page 24
up).
“Section 2.2, The Remote Loop Back Mode” on page 24
3
D
ESCRIPTION
for more details. (internal pull-
“Section 2.2,
REV. 1.0.8

Related parts for XRT82D20IW