EA EDIP240J-7LWTP ELECTRONIC ASSEMBLY, EA EDIP240J-7LWTP Datasheet - Page 14

LCD Graphic Display Modules & Accessories White/Black Contrast With Touch Screen

EA EDIP240J-7LWTP

Manufacturer Part Number
EA EDIP240J-7LWTP
Description
LCD Graphic Display Modules & Accessories White/Black Contrast With Touch Screen
Manufacturer
ELECTRONIC ASSEMBLY
Datasheet

Specifications of EA EDIP240J-7LWTP

Pixel Density
240 x 128
Fluid Type
FSTN Positive
Module Size (w X H X T)
113 mm x 70 mm x 13 mm
Viewing Area (w X H)
91.18 mm x 56.3 mm
Backlighting
White
Background Color
Black
Operating Temperature Range
- 20 C to + 70 C
Attached Touch Screen
Yes
Interface
RS-232, I2C BUS, or SPI BUS
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
EA eDIP240-7
Page 14
ALL COMMANDS AT A GLANCE
The built-in intelligence allows an easy creation of your individual screen content. Below mentioned
commands can be used either directly via the serial interface (see page 17) or together with the self-
definable macro (see page 18).
Command
Formfeed FF (dez:12)
Carriage Return CR(13)
Linefeed LF (dez:10)
Cursor position
Cursor On / Off
Terminal invisible
Terminal visible
Show revision code
Output string
L: left justified
C: centered
R: right justified
Set font
Font zoom factor
Add. line spacing
Text angle
Text mode
Text blink attribute
String for terminal
Draw rectangle
Draw straight line
Continue straight line
Draw point
Point size/line thickness
Graphic mode
Delete area
Invert area
Fill area
Area with fill pattern
Draw box
Draw frame
Draw frame box
Image from clipboard
Load internal image
Load image
Image zoom factor
Image angle
Image link mode
Image flashing attribute
Send hard copy
Delete display
Invert display
Fill display
Switch display off
Switch display on
Show clip-board
Show current
Delete flashing attribute
Inverted flashing area
Pattern for flashing area
Set flashing time
Codes
ESC
ESC
ESC
ESC
ESC
ESC
ESC
ESC
^M
^L
^J
G
Q
T
Z
Z
R
U
D
W
W
W
M
O
M
P
C
A
E
V
L
C
R
F
Z
Y
V
B
T
R
D
P
Z
V
L
S
R
T
C
L
Z
V
B
H
L
S
A
E
C
N
L
Z
I
I
I
I
n1
n1
x1
n1
n1
n1
n1
n1
n1
x1
x1
x1
x1
n1
n1
x1
x1
x1
x1
x1
x1
x1
x1
x1
x1
n1
n1
n1
n1
x1
x1
x1
x1
n1
n2
y1
n2
y1
y1
y1
y1
n2
y1
y1
y1
y1
y1
y1
y1
y1
y1
y1
n2
y1
y1
y1
y1
EA eDIP240-7: Command table 1
Display commands (effect on the entire display)
Text ...
Text
x2
x2
x2
x2
x2
x2
x2
x2
x2
no
x2
x2
x2
x2
...
BLH data ...
NUL
y2
y2
y2
y2
y2
y2
y2
y2
y2
y2
y2
y2
y2
Comands for outputting strings
Change/draw rectangular areas
Draw straight lines and points
Commands for terminal mode
Bitmap image commands
Flashing area commands
n1 Draw an area from x1,y1 to x2,y2 with pattern n1 (always set)
n1 Draw a rectangle x1,y1 to x2,y2 with fill pattern n1 (always replace)
n1 Draw a frame of the type n1 from x1,y1 to x2,y2 (always set)
n1 Draw a frame box of the type n1 from x1,y1 to x2,y2 (always replace)
n1 Define flashing area with pattern n1 (on/off) from x1,y1 to x2,y2
Remarks
The contents of the terminal area are deleted and the cursor is placed at pos. (1,1)
Cursor to the beginning of the line on the extreme left
Cursor is set to the next line
n1=column; n2=line; origin upper-left corner (1,1)
n1=0: Cursor is invisible; n1=1: Cursor flashes;
Terminal display not visible; outputs continue to be executed
Terminal display is visible again;
Show revision code on terminal layer e.g. "EA eDIP240-7 V1.1 Rev.B"
A string (...) is output to xx1,yy1. ´NUL´ ($00), 'LF' ($0A) or 'CR' ($0D) = end of string;
several lines are separated by the character '|' ($7C);;
text between two '~' ($7E) characters flashes on/off;
text between two '@' ($40) characters flashes inversely;
Set font with the number n1 (0..16)
n1 = X zoom factor (1x..4x); n2 = Y zoom factor (1x..4x)
Insert n1 pixels between two lines of text as additional line spacing
Text output angle: n1=0: 0°; n1=1: 90°
Set mode n1: 1=set; 2=delete; 3=inverse; 4=replace; 5=inverse replace;
n1: 0=text solid, blink off; 1=text blink on/off; 2=text blink inverted;
Command for outputting a string in a macro to the terminal
Draw four straight lines as a rectangle from x1,y1 to x2,y2
Draw straight line from x1,y1 to x2,y2
Draw a straight line from last end point to x1, y1
Set one dot at coordinates x1, y1
n1 = X-Punktgröße (1..15); n2 = Y-Punktgröße (1..15);
Drawing mode n1: 1=set; 2=delete; 3=inverse;
Delete an area from x1,y1 to x2,yy2 (all pixels out)
Invert an area from x1,y1 to x2,y2 (invert all pixels
Fill an area from x1,y1 to x2,y2 (all pixels on)
The current contents of the clipboard are loaded to x1,y1 with all the image attributes
Load internal image with the no. (0..255) from EEPROM to x1,y1
Load an image to x1,y1; see image structure for image data
n1 = X zoom factor (1x..4x); n2 = Y zoom factor (1x..4x)
Output angle: n1=0: 0°; n1=1: 90°; n1=2: 180°; n1=3: 270°
Mode n1: 1=set; 2=delete; 3=inverse; 4=replace; 5=inverse replace
n1=0 Image attribute blink off; n1=1 image blink mode on/off; n1=2 image blink mode
inverse
A full image is requested in Windows BMP format. The image header is sent first via
RS232, followed by the actual image data (9662 bytes).
Delete display contents (all pixels off)
Invert display contents (invert all pixels)
Fill display contents (all pixels on)
Display contents become invisible but are retained, commands continue to be possible
Display contents become visible again
Show content of clip-board. Standard display output is no longer visible
Switch back to noraml operation. Standard display output is visible
Delete the flashing attribute from x1,y1 to x2,y2
Define an inverted flashing area from x1,y1 to x2,y2
Set the flashing time n1= 1..15 in 1/10s; 0=deactivate flashing function
Specifications may be changed without
prior notice. Printing error reserved
reset
visibl
visibl
after
1,1
1,1
1,1
1,1
1
0
0
4
0
0
1
0
4
0
6

Related parts for EA EDIP240J-7LWTP