OKL-T/6-W12P-C Murata Power Solutions Inc, OKL-T/6-W12P-C Datasheet - Page 11

DC/DC Converters & Regulators 12Vin .59-5.5Vout 6A 30W Pos Polarity

OKL-T/6-W12P-C

Manufacturer Part Number
OKL-T/6-W12P-C
Description
DC/DC Converters & Regulators 12Vin .59-5.5Vout 6A 30W Pos Polarity
Manufacturer
Murata Power Solutions Inc
Datasheet

Specifications of OKL-T/6-W12P-C

Output Power
30 W
Input Voltage Range
4.5 V to 14 V
Input Voltage (nominal)
12 V
Number Of Outputs
1
Package / Case Size
12.2 mm x 12.2 mm x7.2 mm
Output Voltage
0.591 V to 5.5 V
Product
Non-Isolated / POL
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
PERFORMANCE DATA AND OSCILLOGRAMS
100
95
90
85
80
75
70
65
Step Load Transient Response (Vin=12V, Vout=1.2V, Cload=0, Iout=3A to 6A)
0
Effi ciency vs. Line Voltage and Load Current @ +25˚C. (Vout = 1.2V)
On/Off Enable Delay (Vin=12V, Vout=1.2V, Iout=6A, Cload=0)
Trace 2=Vout, 200 mV/div. Trace 4=Iout, 5A/div.
1
Trace 4=Enable, Trace2=Vout
2
Load Curre nt (Amps)
3
V
V
V
IN
IN
IN
= 4.5V
= 12V
= 14V
4
www.murata-ps.com
5
6
Output Ripple and Noise (Vin=12V, Vout=1.2V, Iout=6A, Cload=0, ScopeBW=20MHz)
Step Load Transient Response (Vin=12V, Vout=1.2V, Cload=0, Iout=6A to 3A)
Maximum Current Temperature Derating at Sea Level (Vin=12V, Vout=1.2V)
7
6
5
4
3
2
1
0
20
Programmable Output 6-Amp iLGA SMT PoLs
25
30
Trace 2=Vout, 200 mV/div. Trace 4=Iout, 5A/div.
09 May 2011
35
40
OKL-T/6-W12 Series
45
Ambient Temperature (ºC)
MDC_OKL-T/6-W12 Series.A09 Page 11 of 18
50
55
60
100 LFM
65 LFM
email: sales@murata-ps.com
65
70
75
80
85
90

Related parts for OKL-T/6-W12P-C