OKL-T/6-W12P-C Murata Power Solutions Inc, OKL-T/6-W12P-C Datasheet - Page 2

DC/DC Converters & Regulators 12Vin .59-5.5Vout 6A 30W Pos Polarity

OKL-T/6-W12P-C

Manufacturer Part Number
OKL-T/6-W12P-C
Description
DC/DC Converters & Regulators 12Vin .59-5.5Vout 6A 30W Pos Polarity
Manufacturer
Murata Power Solutions Inc
Datasheet

Specifications of OKL-T/6-W12P-C

Output Power
30 W
Input Voltage Range
4.5 V to 14 V
Input Voltage (nominal)
12 V
Number Of Outputs
1
Package / Case Size
12.2 mm x 12.2 mm x7.2 mm
Output Voltage
0.591 V to 5.5 V
Product
Non-Isolated / POL
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Performance Specifi cations and Ordering Guide
Product Label
Because of the small size of these products, the product label contains a
character-reduced code to indicate the model number and manufacturing date
code. Not all items on the label are always used. Please note that the label
differs from the product photograph. Here is the layout of the label:
The label contains three rows of information:
First row – Murata Power Solutions logo
Second row – Model number product code (see table)
Third row – Manufacturing date code and revision level
ORDERING GUIDE
Model Number
OKL-T/6-W12P-C
OKL-T/6-W12N-C
OKL2-T/6-W12P-C 0.591-5.5
OKL2-T/6-W12N-C 0.591-5.5
PART NUMBER STRUCTURE
The output range is limited by Vin. See detailed specs.
All specifi cations are at nominal line voltage, Vout=nominal (5V) and full load, +25 deg.C.
unless otherwise noted.
Output capacitors are 10 μF ceramic. Input cap is 22 μF. See detailed specifi cations.
I/O caps are necessary for our test equipment and may not be needed for your application.
Mfg.
date
code
Figure 2.
0.591-5.5
0.591-5.5
YMDX Rev.
(Volts) ➀
XXXXXX
Label Artwork Layout
Vout
Iout (Amps,
max.)
Product code
Revision level
6
6
6
6
LGA Surface Mount
Sequence/tracking
Non-isolated PoL
Blank = Not installed
2 = Installed
(Watts)
Power
30
30
30
30
Output
Trimmable Output
Voltage Range
R/N (mV p-p)
0.591-5.5Vdc
Max. ➃
20
20
20
20
Maximum Rated Output
OK L 2
Current in Amps
Regulation (max.) Vin nom.
±0.25% ±0.25%
±0.25% ±0.25%
±0.25% ±0.25%
±0.25% ±0.25%
Line
www.murata-ps.com
-
T
Load
f
/
Use adequate ground plane and copper thickness adjacent to the converter.
Ripple and Noise (R/N) and no-load input current are shown at Vout=1V. See specs for details.
6
(Volts)
-
12
12
12
12
W12
Input Voltage Range
The manufacturing date code is four characters:
First character – Last digit of manufacturing year, example 2009
Second character – Month code (1 through 9 and O through D)
Third character – Day code (1 through 9 = 1 to 9, 10=O and
Fourth character – Manufacturing information
4.5-14Vdc
11 through 31 = A through Z)
(Volts) ➀
4.5-14
4.5-14
4.5-14
4.5-14
Range
OKL2-T/6-W12P-C
OKL2-T/6-W12N-C
OKL-T/6-W12P-C
OKL-T/6-W12N-C
N
Model Number
-
Input
Programmable Output 6-Amp iLGA SMT PoLs
Iin, no load
C
(mA) ➃
On/Off Polarity
20
20
20
20
RoHS Hazardous
Substance Compliance
P = Positive Polarity
N = Negative Polarity
C = RoHS-6 (does not claim EU RoHS exemption
7b–lead in solder)
09 May 2011
Iin, full load
(Amps)
2.69
2.69
2.69
2.69
OKL-T/6-W12 Series
Product Code
91% 93%
91% 93%
91% 93%
91% 93%
Min.
Effi ciency
L01106
L00106
L21106
L20106
MDC_OKL-T/6-W12 Series.A09 Page 2 of 18
Typ.
Polarity
On/Off
Neg.
Neg.
Pos.
Pos.
email: sales@murata-ps.com
Track
Seq/
yes
yes
no
no
0.48x0.48x0.283 max
0.48x0.48x0.283 max
0.48x0.48x0.283 max
0.48x0.48x0.283 max
Package - Pinout P83
(12.2x12.2x7.2) max
(12.2x12.2x7.2) max
(12.2x12.2x7.2) max
(12.2x12.2x7.2) max
inches (mm)
Case C83