H5CX-AD-N AC24/DC12-24 Omron, H5CX-AD-N AC24/DC12-24 Datasheet - Page 31

Stopwatches / Timers SCREW TERM RLY OUT Multi-Function

H5CX-AD-N AC24/DC12-24

Manufacturer Part Number
H5CX-AD-N AC24/DC12-24
Description
Stopwatches / Timers SCREW TERM RLY OUT Multi-Function
Manufacturer
Omron
Series
H5CXr
Datasheet

Specifications of H5CX-AD-N AC24/DC12-24

Timing Range
0.001 s to 9999 Hrs
Supply Voltage
12 V to 24 V
Current Rating (max)
100 mA
Display Type
4 Digit LCD Backlight
Product
Digital Timer
Termination Style
Screw
Time Range
0.001s-9999hrs
Power Consumption
2.4W
Reset Time
20ms
Character Size
11.5mm
Mounting Type
Panel
Time Range Min
0.001s
Supply Voltage Min
12V
Connector Type
Screw Terminal
Relay Type
Integrated
Function
Programmable (Multi-Function)
Circuit
SPDT (1 Form C)
Delay Time
0.001 Sec ~ 9999 Hrs
Output Type
Mechanical Relay
Contact Rating @ Voltage
5A @ 250VAC
Voltage - Supply
12 ~ 24VDC, 24VAC
Timing Adjustment Method
DIP Switches
Timing Initiate Method
Input Voltage, Trigger Signal
No. Of Digits / Alpha
4
Rohs Compliant
Yes
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
For Use With
PNP/NPN
Lead Free Status / RoHS Status
Lead free / RoHS Compliant, Lead free / RoHS Compliant
Timer/Twin Timer Selection Mode (Function Selection)
Select whether the H5CX is used as a timer or a twin timer in timer/twin timer selection mode.
The H5CX is also equipped with a DIP switch monitor function, a convenient function that enables the settings of the DIP switch pins to be
confirmed using the front display.
*1. When the mode is changed to timer/twin timer selection mode, the present value is reset and output turns OFF.
*2. Setting changes made in timer/twin timer selection mode are enabled when the mode is changed to run mode.
Timing operation is not performed in timer/twin timer selection mode.
If settings are changed, the HC5X is automatically reset (present value initialized, output turned OFF).
*2
Power ON
1 s min.
+
1
*1
Timer/Twin
timer selection
DIP switch
monitor
Caution
Select either
Note: The H5CX is factory-set for timer operation.
Confirm the status of DIP switch pins 1 to 8 using the
Note: 1. This display is not supported with H5CX-L8@-N.
To change the mode to timer/twin timer selection mode,
hold down the
down. The
key is pressed first, the mode will not change.
OFF
ON
2. This display is only possible when DIP switch pin 1 (DIP switch settings
enable/disable) is set to ON (enable).
1 2 3 4 5 6 7 8
Example
keys.
tim
1
key must be pressed before the key. If the
timer operation or
1
key for 1 s min. with the
Key
twn
twin timer operation using the
key held
H5CX-A@-N/-L@-N
Indicates that DIP switch pin 8 is ON.
Indicates that DIP switch pin 7 is OFF.
Indicates that DIP switch pin 6 is ON.
Indicates that DIP switch pin 5 is OFF.
Indicates that DIP switch pin 4 is ON.
Indicates that DIP switch pin 3 is OFF.
Indicates that DIP switch pin 2 is ON.
Indicates that DIP switch pin 1 is ON.
keys.
1
Key
31