H5CX-AD-N AC24/DC12-24 Omron, H5CX-AD-N AC24/DC12-24 Datasheet - Page 35

Stopwatches / Timers SCREW TERM RLY OUT Multi-Function

H5CX-AD-N AC24/DC12-24

Manufacturer Part Number
H5CX-AD-N AC24/DC12-24
Description
Stopwatches / Timers SCREW TERM RLY OUT Multi-Function
Manufacturer
Omron
Series
H5CXr
Datasheet

Specifications of H5CX-AD-N AC24/DC12-24

Timing Range
0.001 s to 9999 Hrs
Supply Voltage
12 V to 24 V
Current Rating (max)
100 mA
Display Type
4 Digit LCD Backlight
Product
Digital Timer
Termination Style
Screw
Time Range
0.001s-9999hrs
Power Consumption
2.4W
Reset Time
20ms
Character Size
11.5mm
Mounting Type
Panel
Time Range Min
0.001s
Supply Voltage Min
12V
Connector Type
Screw Terminal
Relay Type
Integrated
Function
Programmable (Multi-Function)
Circuit
SPDT (1 Form C)
Delay Time
0.001 Sec ~ 9999 Hrs
Output Type
Mechanical Relay
Contact Rating @ Voltage
5A @ 250VAC
Voltage - Supply
12 ~ 24VDC, 24VAC
Timing Adjustment Method
DIP Switches
Timing Initiate Method
Input Voltage, Trigger Signal
No. Of Digits / Alpha
4
Rohs Compliant
Yes
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
For Use With
PNP/NPN
Lead Free Status / RoHS Status
Lead free / RoHS Compliant, Lead free / RoHS Compliant
Connections
Block Diagram
Terminal Arrangement
(–)
Input Connections
The inputs of the H5CX-B are no-voltage (short-circuit or open) inputs or voltage inputs.
No-voltage Inputs (NPN Inputs)
Open Collector
No-voltage Input Signal Levels
Voltage Inputs (PNP Inputs)
No-contact Input (NPN Transistor)
Voltage Input Signal Levels
Note: 1. The DC voltage must be 30 VDC max.
0 V
No-contact
input
Contact input
High level (Input ON): 4.5 to 30 VDC
Low level (Input OFF): 0 to 2 VDC
6
1
PLC or
sensor
7
2
(+)
2. Input resistance: Approx. 4.7 kΩ
12
8
3
Sensor
OUT 2
Note: Operate with transistor ON
9
4
6
Input circuits
Short-circuit level (Transistor ON)
• Residual voltage: 3 V max.
• Impedance when ON: 1 kΩ max.
Open level (Transistor OFF)
• Impedance when OFF: 100 kΩ min.
Use contacts which can adequately switch 5 mA at 10 V
(Basic insulation)
10
13
5
(The leakage current is approx. 12 mA when the impedance is 0 Ω.)
Output circuit
7
Note: Operate with transistor OFF
6
OUT 1
8
7
9
Note: 1. The power supply and input circuit
8
Internal control
10
9
circuit
2. Terminals 1 and 6 are connected
3. Terminals 7 and 10 have the same
10
are not isolated.
internally.
reset function. The same function will
be performed whichever terminal is
connected. Terminals 7 and 10 are
not connected internally, however, so
do not use them for cross-over wiring.
Voltage Output
Sensor
Power supply
circuit
Display circuit
Key switch
Note: Operate with transistor ON
No-contact Input (PNP Transistor)
circuit
6
7
8
Sensor
9
10
Note: Operate with transistor ON
6
7
Contact Input
Input Circuits
Signal, Reset, and Gate Input
No-voltage Inputs (NPN Inputs)
IN
Transistor Output
8
• The transistor output of
• The diode connected to
the H5CX is insulated
from the internal circuitry
by a photocoupler, so the
transistor output can be
used as both NPN and
PNP output.
the collector of the output
transistor is used to
absorb inverted voltage
that is generated when an
inductive load is
connected to the H5CX.
Note: Operate with relay ON
9
6
10
7
1 kΩ
8
+14 V
9
Internal
circuit
Contact Input
10
• Leakage current:
• Switching capacity: 5 mA min.
• Residual voltage:
• Operating voltage: 10 VDC
NPN Output
DC Two-wire Sensor
Note: Operate with relay ON
Applicable Two-wire Sensor
Power for load
6
Voltage Inputs (PNP Inputs)
IN
Note: Operate with transistor ON
Approx. 4.7 kΩ
7
6
Timer
+
Load
Power for load
1.5 mA max.
3.0 VDC max.
8
7
H5CX-B@-N
9
+
8
PNP Output
10
9
Load
Inductive
load
Power for load
Internal
circuit
10
+
35